-
Covered self-expandable metal stents for distal biliary obstruction from pancreatic carcinoma: what type of stent is preferred?
-
Hideyuki Shiomi, Ryota Nakano, Shogo Ota
-
Clin Endosc 2022;55(3):369-371. Published online May 11, 2022
-
DOI: https://doi.org/10.5946/ce.2022.122
-
-
PDF PubReader ePub
-
Citations
Citations to this article as recorded by 
- A case of delayed pancreatic fistula after covered self-expandable metallic stent deployment for pancreatic head cancer
Shogo Ota, Hideyuki Shiomi, Ryota Nakano, Takashi Nishimura, Hirayuki Enomoto, Hiroko Iijima Clinical Journal of Gastroenterology.2023; 16(2): 303. CrossRef - Endoscopic ultrasound-guided biliary drainage for distal malignant biliary obstruction: a prospective 3-year multicenter Egyptian study
K.M. Ragab, M Abdel-Hameed, M Gouda, H Katamish, A Madkour, H Atalla, H Hamed, G.E. Shiha, O Abdallah, R.H. Agwa, E Ghoneem Acta Gastro Enterologica Belgica.2023; 86(1): 26. CrossRef
-
3,118
View
-
153
Download
-
2
Web of Science
-
2
Crossref
-
Endoscopic Ultrasound-Guided Gastroenterostomy for Afferent Loop Syndrome
-
Hideyuki Shiomi, Arata Sakai, Ryota Nakano, Shogo Ota, Takashi Kobayashi, Atsuhiro Masuda, Hiroko Iijima
-
Clin Endosc 2021;54(6):810-817. Published online November 15, 2021
-
DOI: https://doi.org/10.5946/ce.2021.234
-
-
Abstract
PDF PubReader ePub
- Afferent loop syndrome (ALS) is a mechanical obstruction of the afferent limbs after gastrectomy with gastrojejunostomy reconstruction. Patients with cancer recurrence require immediate and less invasive treatment because of their poor condition. Percutaneous transhepatic/transluminal drainage (PTD) and endoscopic enteral stenting offer reasonable palliative treatment for malignant ALS but are not fully satisfactory in terms of patient quality of life (QoL) and stent patency. Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) using a lumen-apposing metal stent may address these shortcomings. Clinical data from 11 reports showed that all patients who had undergone EUS-GE had positive technical and clinical outcomes. The adverse event rate was 11.4%, including only mild or moderate abdominal pain, with no severe adverse events. Indirect comparative studies indicated that patients who had undergone EUS-GE had a significantly superior QoL, a higher clinical success rate, and a lower reintervention rate than those who had undergone PTD or endoscopic enteral stenting. Although the evidence is limited, EUS-GE may be considered as a first-line treatment for malignant ALS because it has better clinical outcomes than other less invasive treatments, such as PTD or endoscopic enteral stenting. Further prospective randomized control trials are necessary to establish EUS-GE as a standard treatment for ALS.
-
Citations
Citations to this article as recorded by 
- Endoscopic ultrasound-guided gastroenterostomy, with focus on technique and practical tips
Chi-Ying Yang, Wen-Hsin Huang, Hsing-Hung Cheng Clinical Endoscopy.2025; 58(2): 201. CrossRef - Endoscopic ultrasound‐guided gastrointestinal anastomosis: Are we there yet?
Vinay Dhir, Cesar Jaurrieta‐Rico, Vivek Kumar Singh Digestive Endoscopy.2024; 36(9): 981. CrossRef - Endoscopic ultrasound-guided gastroenterostomy using a novel dumbbell-shaped fully covered metal stent for afferent loop syndrome with long interluminal distance
Hideyuki Shiomi, Ryota Nakano, Shogo Ota, Hiroko Iijima Endoscopy.2023; 55(S 01): E362. CrossRef - Endoscopic Ultrasound-Guided Gastrojejunostomy for Malignant Afferent Loop Syndrome Using a Fully Covered Metal Stent: A Multicenter Experience
Saburo Matsubara, Sho Takahashi, Naminatsu Takahara, Keito Nakagawa, Kentaro Suda, Takeshi Otsuka, Yousuke Nakai, Hiroyuki Isayama, Masashi Oka, Sumiko Nagoshi Journal of Clinical Medicine.2023; 12(10): 3524. CrossRef - Endoscopic ultrasound guided gastroenterostomy: Technical details updates, clinical outcomes, and adverse events
Jian Wang, Jin-Long Hu, Si-Yu Sun World Journal of Gastrointestinal Endoscopy.2023; 15(11): 634. CrossRef - Endoscopic ultrasound-guided intra-afferent loop entero-enterostomy using a forward-viewing echoendoscope and insertion of a metal stent
Yuki Kawasaki, Susumu Hijioka, Kosuke Maehara, Kiichi Tamada, Takuji Okusaka, Yutaka Saito Endoscopy.2022; 54(S 02): E815. CrossRef - Endoscopic ultrasound‐guided gastrojejunostomy for malignant afferent loop syndrome with hemorrhage in a patient with recurrent peritoneal dissemination
Kenjiro Yamamoto, Takayoshi Tsuchiya, Ryosuke Tonozuka, Shuntaro Mukai, Hiroyuki Kojima, Noriyuki Hirakawa, Takao Itoi Journal of Hepato-Biliary-Pancreatic Sciences.2022;[Epub] CrossRef - Current status of, and challenges posed by, endoscopic ultrasound‐guided anastomosis of the digestive tract in patients with afferent loop syndrome
Toshio Fujisawa, Hiroyuki Isayama Digestive Endoscopy.2022; 34(7): 1440. CrossRef
-
5,242
View
-
170
Download
-
8
Web of Science
-
8
Crossref
-
Endoscopic Self-Expandable Metal Stent Placement for Malignant Afferent Loop Obstruction After Pancreaticoduodenectomy: A Case Series and Review
-
Arata Sakai, Hideyuki Shiomi, Takao Iemoto, Ryota Nakano, Takuya Ikegawa, Takashi Kobayashi, Atsuhiro Masuda, Yuzo Kodama
-
Clin Endosc 2020;53(4):491-496. Published online March 3, 2020
-
DOI: https://doi.org/10.5946/ce.2019.145
-
-
Abstract
PDF PubReader ePub
- In this study, we assessed a series of our cases in which endoscopic self-expandable metal stents (SEMSs) were used to treat malignant afferent loop obstruction (ALO) that arose after pancreaticoduodenectomy (PD). We retrospectively examined the records of 7 patients who underwent endoscopic SEMS placement for malignant ALO following PD. Clinical success was achieved in all cases. The median procedure time was 30 min (range, 15–50 min). There were no cases of stent occlusion, and no procedure-related adverse events were encountered. All patients died of their primary disease, and the median overall survival period was 155 days (range, 96–374 days). A re-intervention involving endoscopic ultrasound-guided hepaticogastrostomy combined with antegrade stenting was performed for obstructive jaundice and acute cholangitis in 1 case. In conclusion, endoscopic SEMS placement may be an effective and safe treatment for malignant ALO that arises after PD.
-
Citations
Citations to this article as recorded by 
- Early and late effects of endoscopic interventions in patients with malignant afferent loop syndrome: A single‐center experience and literature review
Kenjiro Yamamoto, Takao Itoi, Yukitoshi Matsunami, Atsushi Sofuni, Takayoshi Tsuchiya, Shuntaro Mukai, Hiroyuki Kojima, Hirohito Minami, Ryosuke Nakatsubo, Ryosuke Tonozuka Journal of Hepato-Biliary-Pancreatic Sciences.2024; 31(2): 120. CrossRef - Efficacy of endoscopic ultrasound‐guided gastroenterostomy using self‐expandable metallic stent for afferent loop syndrome: A single‐center retrospective study
Yuya Hagiwara, Susumu Hijioka, Yoshikuni Nagashio, Yuta Maruki, Akihiro Ohba, Yuki Kawasaki, Kotaro Takeshita, Tetsuro Takasaki, Daiki Agarie, Hidenobu Hara, Shin Yagi, Soma Fukuda, Masaru Kuwada, Daiki Yamashige, Kohei Okamoto, Mark Chatto, Shunsuke Kond Journal of Gastroenterology and Hepatology.2024; 39(10): 2136. CrossRef - Successful metal stent placement using short single-balloon endoscope for afferent loop syndrome after pancreaticoduodenectomy
Takuto Furukawa, Yuichi Takano, Jun Noda, Masataka Yamawaki, Tetsushi Azami, Fumitaka Niiya, Fumiya Nishimoto, Naotaka Maruoka, Masatsugu Nagahama Progress of Digestive Endoscopy.2024; 104(1): 98. CrossRef - Antegrade metallic stent placement using a slim cholangioscope for malignant afferent loop obstruction
Haruo Miwa, Ritsuko Oishi, Kazuki Endo, Hiromi Tsuchiya, Akihiro Funaoka, Yuichi Suzuki, Shin Maeda Endoscopy.2024; 56(S 01): E774. CrossRef - The Role of Endoscopic Management in Afferent Loop Syndrome
Clement Chun Ho Wu, Elizabeth Brindise, Rami El Abiad, Mouen A. Khashab Gut and Liver.2023; 17(3): 351. CrossRef - Simultaneous stent placement for biliary and afferent loop obstruction due to tumor recurrence after pancreatoduodenectomy
Tatsunori Satoh, Hirotoshi Ishiwatari, Kazuma Ishikawa, Hidenori Kimura, Hiroyuki Matsubayashi, Hiroyuki Ono Endoscopy.2022; 54(09): E524. CrossRef - Extra-anatomic percutaneous stenting of a malignant afferent loop obstruction following pancreaticoduodenectomy
Stefan Lam, Sarah Khan, Robert Hutchins, Tim Fotheringham International Journal of Gastrointestinal Intervention.2022; 11(2): 77. CrossRef - Endoscopic Transluminal Stent Placement for Malignant Afferent Loop Obstruction
Chinatsu Yonekura, Takashi Sasaki, Takafumi Mie, Takeshi Okamoto, Tsuyoshi Takeda, Takaaki Furukawa, Yuto Yamada, Akiyoshi Kasuga, Masato Matsuyama, Masato Ozaka, Naoki Sasahira Journal of Clinical Medicine.2022; 11(21): 6357. CrossRef - Clinical management for malignant afferent loop obstruction
Arata Sakai, Hideyuki Shiomi, Atsuhiro Masuda, Takashi Kobayashi, Yasutaka Yamada, Yuzo Kodama World Journal of Gastrointestinal Oncology.2021; 13(7): 684. CrossRef - Clinical management for malignant afferent loop obstruction
Arata Sakai, Hideyuki Shiomi, Atsuhiro Masuda, Takashi Kobayashi, Yasutaka Yamada, Yuzo Kodama World Journal of Gastrointestinal Oncology.2021; 13(7): 509. CrossRef - Endoscopic Ultrasound-Guided Gastroenterostomy for Afferent Loop Syndrome
Hideyuki Shiomi, Arata Sakai, Ryota Nakano, Shogo Ota, Takashi Kobayashi, Atsuhiro Masuda, Hiroko Iijima Clinical Endoscopy.2021; 54(6): 810. CrossRef - Percutaneous- and EUS-guided gastroenterostomy for malignant afferent limb syndrome
Dayyan Adoor, Zachary L. Smith VideoGIE.2020; 5(11): 542. CrossRef
-
5,537
View
-
113
Download
-
9
Web of Science
-
12
Crossref
|