-
Contamination Rates in Duodenoscopes Reprocessed Using Enhanced Surveillance and Reprocessing Techniques: A Systematic Review and Meta-Analysis
-
Shivanand Bomman, Munish Ashat, Navroop Nagra, Mahendran Jayaraj, Shruti Chandra, Richard A Kozarek, Andrew Ross, Rajesh Krishnamoorthi
-
Clin Endosc 2022;55(1):33-40. Published online January 3, 2022
-
DOI: https://doi.org/10.5946/ce.2021.212
-
-
Abstract
PDFSupplementary MaterialPubReaderePub
- Background
/Aims: Multiple outbreaks of multidrug-resistant organisms have been reported worldwide due to contaminated duodenoscopes. In 2015, the United States Food and Drug Administration recommended the following supplemental enhanced surveillance and reprocessing techniques (ESRT) to improve duodenoscope disinfection: (1) microbiological culture, (2) ethylene oxide sterilization, (3) liquid chemical sterilant processing system, and (4) double high-level disinfection. A systematic review and meta-analysis was performed to assess the impact of ESRT on the contamination rates.
Methods A thorough and systematic search was performed across several databases and conference proceedings from inception until January 2021, and all studies reporting the effectiveness of various ESRTs were identified. The pooled contamination rates of post-ESRT duodenoscopes were estimated using the random effects model.
Results A total of seven studies using various ESRTs were incorporated in the analysis, which included a total of 9,084 post-ESRT duodenoscope cultures. The pooled contamination rate of the post-ESRT duodenoscope was 5% (95% confidence interval [CI]: 2.3%–10.8%, inconsistency index [I2]=97.97%). Pooled contamination rates for high-risk organisms were 0.8% (95% CI: 0.2%–2.7%, I2=94.96).
Conclusions While ESRT may improve the disinfection process, a post-ESRT contamination rate of 5% is not negligible. Ongoing efforts to mitigate the rate of contamination by improving disinfection techniques and innovations in duodenoscope design to improve safety are warranted.
-
Citations
Citations to this article as recorded by
- Recommendations and guidelines for endoscope reprocessing: Current position statement of digestive endoscopic society of Taiwan
Wei-Kuo Chang, Chen-Ling Peng, Yen-Wei Chen, Cheuk-Kay Sun, Chieh-Chang Chen, Tao-Chieh Liu, Yin-Yi Chu, I-Fang Tsai, Chen-Shuan Chung, Hsiao-Fen Lin, Fang-Yu Hsu, Wei-Chen Tai, Hsi-Chang Lee, Hsu-Heng Yen, E-Ming Wang, Shu-Hui Chen, Cheng-Hsin Chu, Ming- Journal of Microbiology, Immunology and Infection.2024; 57(2): 211. CrossRef - Duodenoscopes With Disposable Elevator Caps—An Incremental Reduction in Infection Risk for Patients
Melinda Wang, Graham M. Snyder JAMA Internal Medicine.2023; 183(3): 200. CrossRef - Transmission of oral microbiota to the biliary tract during endoscopic retrograde cholangiography
Maria Effenberger, Ramona Al-Zoairy, Ronald Gstir, Ivo Graziadei, Hubert Schwaighofer, Herbert Tilg, Heinz Zoller BMC Gastroenterology.2023;[Epub] CrossRef - Role of peroral cholangioscopy and pancreatoscopy in the diagnosis and treatment of biliary and pancreatic disease: past, present, and future
Harishankar Gopakumar, Neil R. Sharma Frontiers in Gastroenterology.2023;[Epub] CrossRef - Performance of single-use duodenoscopes for ERCP: a systematic review and meta-analysis
Harishankar Gopakumar, Ishaan Vohra, Neil R. Sharma, Srinivas R. Puli iGIE.2022; 1(1): 77. CrossRef
-
4,612
View
-
235
Download
-
4
Web of Science
-
5
Crossref
|