Alterations of the expression pattern of mucins and trefoil peptides have been described in gastric adenocarcinomas and in their precursor lesions. The aim of this study was to determine the progression patterns of intestinal metaplasia (IM) subtypes by analyzing the expression patterns of TFF1 and MUC5AC in different subtypes of IM of the stomach.
Endoscopic gastric biopsies of the antrum and body were obtained from patients with dyspepsia and endoscopic IM. Alcian blue/periodic acid-Schiff staining and the high iron diamine technique were used to classify the subtypes of IM. Immunoreactivity for MUC5AC and TFF1 was estimated in different types of IM.
IM was detected in 128 samples from 80 patients; type I was found in 48 samples, type II was found in 37 samples, and type III was found in 43 samples. There was a gradual decrease in MUC5AC and TFF1 expression during the progression of IM from type I to type III via the type II intermediate.
This downregulation of MUC5AC and TFF1 expression may challenge the sequential progression of IM from type I to type III via the type II intermediate, and it might be associated with gastric carcinogenesis.
Citations
It is believed that disposable biopsy forceps are more costly than reusable biopsy forceps. In this study, we evaluated performance and cost of disposable forceps versus reusable forceps in esophagogastroduodenoscopic biopsy.
Between October 2009 and July 2010, we enrolled 200 patients undergoing esophagogastroduodenoscopic biopsy at Seoul St. Mary's Hospital. Biopsies were performed with 100 disposable or 5 reusable forceps by random assignment. Seventy-five additional patients were studied to estimate durability of reusable forceps. The assisting nurses estimated the performance of the forceps. The evaluation of costs included purchase prices and reprocessing costs. The adequacy of the sample was estimated according to the diameter of the obtained tissue.
Performance of disposable forceps was estimated as excellent in 97.0%, good in 2.0% and adequate in 1.0%. Reusable forceps were estimated as excellent in 36.0%, good in 36.0%, adequate in 25.1% and inadequate in 2.9%. The performance of reusable forceps declined with the number of uses. The reprocessing cost of reusable forceps for one biopsy session was calculated as ₩8,021. The adequacy of the sample was excellent for both forceps.
Disposable forceps showed excellent performance. Considering the reprocessing costs of reusable forceps, usage of disposable forceps with a low price should be considered.
Citations