Skip Navigation
Skip to contents

Clin Endosc : Clinical Endoscopy

OPEN ACCESS

Search

Page Path
HOME > Search
1 "Kenichiro Seki"
Filter
Filter
Article category
Keywords
Publication year
Authors
Original Article
Laser-cut-type versus braided-type covered self-expandable metallic stents for distal biliary obstruction caused by pancreatic carcinoma: a retrospective comparative cohort study
Koh Kitagawa, Akira Mitoro, Takahiro Ozutsumi, Masanori Furukawa, Yukihisa Fujinaga, Kenichiro Seki, Norihisa Nishimura, Yasuhiko Sawada, Kosuke Kaji, Hideto Kawaratani, Hiroaki Takaya, Kei Moriya, Tadashi Namisaki, Takemi Akahane, Hitoshi Yoshiji
Clin Endosc 2022;55(3):434-442.   Published online October 28, 2021
DOI: https://doi.org/10.5946/ce.2021.161
AbstractAbstract PDF
Background
/Aims: Covered self-expandable metallic stents (CMSs) are widely used for malignant distal biliary obstructions (MDBOs) caused by pancreatic carcinoma. This study compared the efficacy and safety of the laser-cut-type and braided-type CMSs.
Methods
To palliate MDBOs caused by pancreatic carcinoma, the laser-cut-type CMSs was used from April 2014 to March 2017, and the braided-type CMSs was used from April 2017 to March 2019. The tested self-expandable metallic stents were equipped with different anti-migration systems.
Results
In total, 47 patients received CMSs for MDBOs (24 laser-cut type, 23 braided-type). The time to recurrent biliary obstruction (TRBO) was significantly longer in the braided-type CMSs (p=0.0008), and the median time to stent dysfunction or patient death was 141 and 265 days in the laser-cut-type CMSs and braided-type CMSs, respectively (p=0.0023). Stent migration was the major cause of stent dysfunction in both groups, which occurred in 37.5% of the laser-cut-type CMSs and 13.0% of the braidedtype CMSs. There were no differences in the survival duration between the groups.
Conclusions
The TRBO was significantly longer for the braided-type CMSs with an anti-migration system than for the laser-cuttype. Stent migration tended to be less frequent with the braided-type CMSs than with the laser-cut-type CMSs.

Citations

Citations to this article as recorded by  
  • Comparison of the Usefulness of Covered and Uncovered Laser‐cut Metal Stents
    Toshio Fujisawa, Masao Toki, Kei Saito, Yuta Hasegawa, Eisuke Iwasaki, Michihiro Saito, Katsuya Kitamura, Ryosuke Tonozuka, Takao Itoi, Ken Ito, Keiko Kaneko, Naminatsu Takahara, Tadakazu Hisamatsu, Hiroyuki Isayama
    DEN Open.2026;[Epub]     CrossRef
  • Multi-Hole Self-Expandable Metallic Stent for Malignant Distal Biliary Obstruction: A Literature Review
    Koh Kitagawa, Shohei Asada, Jun-ichi Hanatani, Yuki Motokawa, Yui Osaki, Tomihiro Iwata, Akira Mitoro, Hitoshi Yoshiji
    Journal of Clinical Medicine.2026; 15(4): 1410.     CrossRef
  • Moving-boundary elastica predicts looped-end braided stent crimping
    Amr F. Mohamed, Philipp Berg, Mark Vekemans, Ted J. Vaughan, Adam J. Griebel, Alessandra Di Lorenzo, Daniel Behme, Stefan Jockenhoevel, Alexander Kopp
    International Journal of Mechanical Sciences.2026; 327: 111959.     CrossRef
  • Prevention of stent migration of covered self-expandable metal stents in distal malignant biliary obstruction: a review of literature
    Jung Won Chun, Woo Hyun Paik, Sang Myung Woo, Jin Ho Choi, In Rae Cho, Woo Jin Lee, Ji Kon Ryu, Yong-Tae Kim, Sang Hyub Lee
    Gastroenterology Report.2025;[Epub]     CrossRef
  • From dogma to individualized care: the potential of 6-mm fully covered self-expandable metal stent in unresectable malignant distal biliary obstruction
    Hyung Ku Chon
    Clinical Endoscopy.2025; 58(4): 630.     CrossRef
  • Duodenal Stenting Is Associated with Longer Biliary Patency in Endoscopic Ultrasound-Guided Biliary Drainage: Potential Role of Braided Biliary Stents
    Mitsuru Sugimoto, Tadayuki Takagi, Rei Suzuki, Yuichi Waragai, Hiroyuki Asama, Hiroshi Shimizu, Kentaro Sato, Kento Osawa, Rei Ohira, Jun Nakamura, Mika Takasumi, Tsunetaka Kato, Takumi Yanagita, Mitsuru Otsuka, Takuto Hikichi, Hiromasa Ohira
    Oncology.2025; 104(8): 863.     CrossRef
  • Braided-type stent versus laser-cut-type stent for patients with unresectable distal malignant biliary obstruction: a randomized controlled trial
    Sho Hasegawa, Takamitsu Sato, Satoru Shinoda, Yusuke Kurita, Tomoki Ogata, Shinichi Nihei, Shin Yagi, Kunihiro Hosono, Itaru Endo, Noritoshi Kobayashi, Kensuke Kubota, Atsushi Nakajima
    Gastrointestinal Endoscopy.2024; 99(5): 739.     CrossRef
  • Removal of Duckbill‐type laser‐cut anti‐reflux metal stents: Clinical evaluation and in vitro study
    Yuto Yamada, Takashi Sasaki, Tsuyoshi Takeda, Takeshi Okamoto, Takafumi Mie, Chinatsu Yonekura, Takaaki Furukawa, Akiyoshi Kasuga, Masato Matsuyama, Masato Ozaka, Takahisa Matsuda, Yoshinori Igarashi, Naoki Sasahira
    DEN Open.2023;[Epub]     CrossRef
  • Comparable Efficacy of Laser-Cut and Braided Self Expanding Metallic Biliary Stent: A Systematic Review and Meta-Analysis
    Priyadarshini Loganathan, Saurabh Chandan, Babu P. Mohan, Shreyas Saligram, Douglas G. Adler
    Digestive Diseases and Sciences.2023; 68(9): 3756.     CrossRef
  • Evaluation of the mechanical properties of current biliary self-expandable metallic stents: axial and radial force, and axial force zero border
    Wataru Yamagata, Toshio Fujisawa, Takashi Sasaki, Rei Ishibashi, Tomotaka Saito, Shuntaro Yoshida, Shizuka No, Kouta Inoue, Yousuke Nakai, Naoki Sasahira, Hiroyuki Isayama
    Clinical Endoscopy.2023; 56(5): 633.     CrossRef
  • Covered self-expandable metal stents for distal biliary obstruction from pancreatic carcinoma: what type of stent is preferred?
    Hideyuki Shiomi, Ryota Nakano, Shogo Ota
    Clinical Endoscopy.2022; 55(3): 369.     CrossRef
  • 7,336 View
  • 308 Download
  • 11 Web of Science
  • 11 Crossref
Close layer

Clin Endosc : Clinical Endoscopy Twitter Facebook
Close layer
TOP