1 "Won Chul Kim"
Filter
Filter
Article category
Keywords
Publication year
Authors
Original Article
Performance and Cost of Disposable Biopsy Forceps in Upper Gastrointestinal Endoscopy: Comparison with Reusable Biopsy Forceps
Chul-Hyun Lim, Myung-Gyu Choi, Won Chul Kim, Jin Soo Kim, Yu Kyung Cho, Jae Myung Park, In Seok Lee, Sang Woo Kim, Kyu Yong Choi, In-Sik Chung
Clin Endosc 2012;45(1):62-66.   Published online March 31, 2012
DOI: https://doi.org/10.5946/ce.2012.45.1.62
AbstractAbstract PDFPubReaderePub
Background/Aims

It is believed that disposable biopsy forceps are more costly than reusable biopsy forceps. In this study, we evaluated performance and cost of disposable forceps versus reusable forceps in esophagogastroduodenoscopic biopsy.

Methods

Between October 2009 and July 2010, we enrolled 200 patients undergoing esophagogastroduodenoscopic biopsy at Seoul St. Mary's Hospital. Biopsies were performed with 100 disposable or 5 reusable forceps by random assignment. Seventy-five additional patients were studied to estimate durability of reusable forceps. The assisting nurses estimated the performance of the forceps. The evaluation of costs included purchase prices and reprocessing costs. The adequacy of the sample was estimated according to the diameter of the obtained tissue.

Results

Performance of disposable forceps was estimated as excellent in 97.0%, good in 2.0% and adequate in 1.0%. Reusable forceps were estimated as excellent in 36.0%, good in 36.0%, adequate in 25.1% and inadequate in 2.9%. The performance of reusable forceps declined with the number of uses. The reprocessing cost of reusable forceps for one biopsy session was calculated as ₩8,021. The adequacy of the sample was excellent for both forceps.

Conclusions

Disposable forceps showed excellent performance. Considering the reprocessing costs of reusable forceps, usage of disposable forceps with a low price should be considered.

Citations

Citations to this article as recorded by  
  • International Delphi Consensus Study on disposable single-use endoscopy: A path to clinical adoption
    Alessandro Repici, Kareem Khalaf, Edoardo Troncone, Sharmila Subramaniam, Cesare Hassan, Pradeep Bhandari, Lars AABAKKEN, Sarah ABERE, Maisam W. AKROUSH, Abed AL-LEHIBI, Eduardo ALBÉNIZ, Asma ALKANDARI, Majid A. ALMADI, Andrea ANDERLONI, Amol BAPAYE, Napo
    Digestive and Liver Disease.2024; 56(2): 322.     CrossRef
  • Single‐use accessories and endoscopes in the era of sustainability and climate change—A balancing act
    Zaheer Nabi, Raymond S. Y. Tang, Sridhar Sundaram, Sundeep Lakhtakia, D. Nageshwar Reddy
    Journal of Gastroenterology and Hepatology.2024; 39(1): 7.     CrossRef
  • Ressourcenschonung aus Sicht der Hygiene
    Susanne Kolbe-Busch, Iris F. Chaberny
    Die Chirurgie.2023; 94(3): 220.     CrossRef
  • An Economic Analysis of Direct Costs of Distal Radius Fixation and the Implications of a Disposable Distal Radius Kit
    Jonathan Lans, Ritsaart F. Westenberg, Svenna H.W.L. Verhiel, Rohit Garg, Jesse B. Jupiter, Neal C. Chen
    Journal of Orthopaedic Trauma.2021; 35(9): e346.     CrossRef
  • Multidisciplinary and Multisociety Practice Guideline on Reprocessing Flexible Gastrointestinal Endoscopes and Endoscopic Accessories
    Dae Young Cheung, Byung Ik Jang, Sang Wook Kim, Jie-Hyun Kim, Hyung Keun Kim, Jeong Eun Shin, Won Jae Yoon, Yong Kang Lee, Kwang Hyun Chung, Soo-Jeong Cho, Hyun Phil Shin, Sun Young Cho, Woon Geon Shin, Kee Don Choi, Byung-Wook Kim, Joong Goo Kwon, Hee Ch
    Clinical Endoscopy.2020; 53(3): 276.     CrossRef
  • Multidisciplinary and Multisociety Practice Guidelines for Reprocessing Flexible Gastrointestinal Endoscopes and Endoscopic Accessories; Korean Association for the Study of the Liver, the Korean Society of Infectious Diseases, Korean College of Helicobact
    Dae Young Cheung, Byung Ik Jang, Sang Wook Kim, Jie-Hyun Kim, Hyung Keun Kim, Jeong Eun Shin, Won Jae Yoon, Yong Kang Lee, Kwang Hyun Chung, Soo-Jeong Cho, Hyun Phil Shin, Sun Young Cho, Woon Geon Shin, Kee Don Choi, Byung-Wook Kim, Joong Goo Kwon, Hee Ch
    The Korean Journal of Medicine.2020; 95(5): 325.     CrossRef
  • Korean Society of Gastrointestinal Endoscopy Guidelines for Endoscope Reprocessing
    Byoung Kwan Son, Byung-Wook Kim, Won Hee Kim, Dae-Sung Myung, Young-Seok Cho, Byung Ik Jang
    Clinical Endoscopy.2017; 50(2): 143.     CrossRef
  • Korean Society of Gastrointestinal Endoscopy (KSGE) Guidelines for Endoscope Reprocessing
    Byung-Wook Kim, Byoung Kwan Son, Won Hee Kim, Dae-Sung Myung, Young-Seok Cho, Byung Ik Jang
    The Korean Journal of Medicine.2017; 92(3): 239.     CrossRef
  • Evaluating Quality and Adequacy of Gastrointestinal Samples Collected using Reusable or Disposable Forceps
    J.A. Cartwright, T.L. Hill, S. Smith, D. Shaw
    Journal of Veterinary Internal Medicine.2016; 30(4): 1002.     CrossRef
  • Current Status of Endoscope Reprocessing in Korea
    Young-Seok Cho
    Clinical Endoscopy.2015; 48(1): 1.     CrossRef
  • Role of Clinical Endoscopy in Emphasizing Endoscope Disinfection
    Ji Kon Ryu, Eun Young Kim, Kwang An Kwon, Il Ju Choi, Ki Baik Hahm
    Clinical Endoscopy.2015; 48(5): 351.     CrossRef
  • High-level disinfection of gastrointestinal endoscope reprocessing
    King-Wah Chiu
    World Journal of Experimental Medicine.2015; 5(1): 33.     CrossRef
  • Is non-woven fabric a useful method of packaging instruments for operation theatres in resource constrained settings?
    GS Devadiga, VMP Thomas, S Shetty, MS Setia
    Indian Journal of Medical Microbiology.2015; 33(2): 243.     CrossRef
  • Steps of Reprocessing and Equipments
    Yong Kook Lee, Jeong Bae Park
    Clinical Endoscopy.2013; 46(3): 274.     CrossRef
  • 8,064 View
  • 107 Download
  • 14 Crossref
Close layer

Clin Endosc : Clinical Endoscopy Twitter Facebook
Close layer
TOP