Brief Report Effective hemostasis under gel immersion endoscopy using inflated balloons on the tip of double balloon endoscope for active bleeding in the small intestine
Shunsuke Horitani1orcid, Natsuko Saito1orcid, Koki Hosoda1orcid, Hironao Matsumoto1orcid, Toshiyuki Mitsuyama1orcid, Takeshi Yamashina1orcid, Masaaki Shimatani1,orcid, Makoto Naganuma2orcid
Clinical Endoscopy 2024;57(3):409-411.
DOI: https://doi.org/10.5946/ce.2023.146
Published online: February 8, 2024

1Department of Gastroenterology and Hepatology, Kansai Medical University Medical Center, Osaka, Japan

2Department of Gastroenterology and Hepatology, Kansai Medical University, Osaka, Japan

Correspondence: Masaaki Shimatani Department of Gastroenterology and Hepatology, Kansai Medical University Medical Center, 10-15 Fumizonocho, Moriguchi, Osaka 570-8507, Japan E-mail: shimatam@hirakata.kmu.ac.jp
• Received: May 29, 2023   • Revised: July 3, 2023   • Accepted: July 7, 2023

© 2024 Korean Society of Gastrointestinal Endoscopy

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 3,666 Views
  • 158 Download
prev next
Securing an endoscopic visual field when identifying the source of gastrointestinal bleeding is difficult because the injected water easily mixes with blood and residue. Performing endoscopic procedures is challenging when the luminal contents are displaced by gas insufflation, which leads to significant discomfort. Gel immersion endoscopy (GIE) using an electrolyte-free gel (VISCOCLEAR; Otsuka Pharmaceutical Factory) has been reported to be useful for securing the visual field during endoscopy for gastrointestinal bleeding.1,2 Particularly in the case of the small intestine, which is frequently filled with blood, GIE is effective for narrow lumens. This gel can easily replace the blood. Insufflation of the endoscope balloon avoids backflow of the gel, enabling it to push away blood and hold the intestinal wall, allowing the endoscope to stay at the targeted position. We also used a BioShield irrigator (US Endoscopy), which allowed additional injection of the gel with a therapeutic device through the accessory channel. In addition, the use of a transparent cap makes it easier to concentrate the gel in front of the endoscope (Fig. 1). Herein, we report the successful treatment of a hemangioma with active bleeding in the small intestine under GIE using inflated balloons on the tip of a double balloon endoscope (DBE).
A 15-year-old boy had been suffering from melena for a month. Esophagogastroduodenoscopy and colonoscopy failed to reveal any signs of active bleeding. Capsule endoscopy was performed to check for small intestinal lesions and detected bloody intestinal fluid in the jejunum, followed by DBE, which revealed a large amount of fresh blood in the jejunum (Fig. 2). The cause of gastrointestinal bleeding was undetectable because the injected water was mixed with blood and the endoscope did not remain at the targeted position. However, by applying GIE using inflated balloons on the tip of the DBE, the visual field was secured, and the bleeding source was detected (Fig. 3, Supplementary Video 1). We immediately injected a hypertonic saline-epinephrine solution at the point of bleeding. Moderately active bleeding allowed us to secure the visual field. We were able to identify the lesion suspicious for a hemangioma as the source of bleeding, which was further performed with complete hemostasis using endoclips (SureClip; Microtech) (Fig. 4). In this case, approximately 80 mL of gel was used. The patient was discharged without complications, and has not suffered from recurrence.
In conclusion, GIE using inflated balloons on the tip of DBE is useful for precise treatment of active gastrointestinal bleeding, for it could facilitate endoscopic maneuvers and allow clear endoscopic view.

Supplementary Video 1.

Effective hemostasis under gel immersion endoscopy using inflated balloons on the tip of double balloon endoscope (https://doi.org/10.5946/ce.2023.146.v1).
Supplementary materials related to this article can be found online at https://doi.org/10.5946/ce.2023.146.
Fig. 1.
The equipment figure for gel immersion endoscopy using double balloon endoscope.
ce-2023-146f1.jpg
Fig. 2.
A large amount of fresh blood in the jejunum.
ce-2023-146f2.jpg
Fig. 3.
Gel immersion endoscopy using inflated balloons on the tip of double balloon endoscope secured the visual field, and the bleeding source was detected.
ce-2023-146f3.jpg
Fig. 4.
(A) After injection of hypertonic saline-epinephrine solution, the lesion suspicious of being hemangioma, which was the source of the bleeding, was visualized. (B) Hemostasis using endoclips was carried out.
ce-2023-146f4.jpg
  • 1. Yano T, Nemoto D, Ono K, et al. Gel immersion endoscopy: a novel method to secure the visual field during endoscopy in bleeding patients (with videos). Gastrointest Endosc 2016;83:809–811.ArticlePubMed
  • 2. Yano T, Takezawa T, Hashimoto K, et al. Gel immersion endoscopy: innovation in securing the visual field - Clinical experience with 265 consecutive procedures. Endosc Int Open 2021;9:E1123–E1127.ArticlePubMedPMC

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • PubReader PubReader
      • ePub LinkePub Link
      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Effective hemostasis under gel immersion endoscopy using inflated balloons on the tip of double balloon endoscope for active bleeding in the small intestine
        Clin Endosc. 2024;57(3):409-411.   Published online February 8, 2024
        Close
      • XML DownloadXML Download
      Figure
      • 0
      • 1
      • 2
      • 3
      Effective hemostasis under gel immersion endoscopy using inflated balloons on the tip of double balloon endoscope for active bleeding in the small intestine
      Image Image Image Image
      Fig. 1. The equipment figure for gel immersion endoscopy using double balloon endoscope.
      Fig. 2. A large amount of fresh blood in the jejunum.
      Fig. 3. Gel immersion endoscopy using inflated balloons on the tip of double balloon endoscope secured the visual field, and the bleeding source was detected.
      Fig. 4. (A) After injection of hypertonic saline-epinephrine solution, the lesion suspicious of being hemangioma, which was the source of the bleeding, was visualized. (B) Hemostasis using endoclips was carried out.
      Effective hemostasis under gel immersion endoscopy using inflated balloons on the tip of double balloon endoscope for active bleeding in the small intestine

      Clin Endosc : Clinical Endoscopy Twitter Facebook
      Close layer
      TOP