Skip Navigation
Skip to contents

Clin Endosc : Clinical Endoscopy

OPEN ACCESS

Articles

Page Path
HOME > Clin Endosc > Volume 56(2); 2023 > Article
Brief Report Side-viewing scope insertion using a large-diameter overtube designed for colonoscopy in a patient with a cascade stomach
Hirokazu Saitoorcid, Yoshitaka Kadowakiorcid, Atsushi Fujimotoorcid, Kana Ohmotoorcid, Shuji Tadaorcid
Clinical Endoscopy 2023;56(2):256-257.
DOI: https://doi.org/10.5946/ce.2022.089
Published online: January 5, 2023

Department of Gastroenterology, Kumamoto City Hospital, Kumamoto, Japan

Correspondence: Hirokazu Saito Department of Gastroenterology, Kumamoto City Hospital, 4-1-60, Higashimachi, Higashi-ku, Kumamoto 862-8505, Japan E-mail: arnestwest@yahoo.co.jp
• Received: February 28, 2022   • Revised: March 4, 2022   • Accepted: March 9, 2022

Copyright © 2023 Korean Society of Gastrointestinal Endoscopy

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 3,118 Views
  • 132 Download
prev next
Endoscopic retrograde cholangiopancreatography (ERCP) is an invaluable procedure for managing biliopancreatic disorders. Successful side-viewing scope insertion into the descending part of the duodenum is the first step in ERCP. However, delivering the side-viewing scope into the descending part of the duodenum is difficult in some patients with a cascade stomach, as the scope is deflected in the stomach. Forced insertion of a side-viewing scope in such patients may tear the gastric mucosa and result in gastric perforation and bleeding due to excessive shearing force on the gastric wall.1,2 To overcome this problem, we used a large-diameter overtube designed for colonoscopy in patients in whom side-viewing scope insertion into the descending part of the duodenum was difficult due to a cascade stomach.
An 88-year-old man who had required biliary stent insertion for acute cholangitis caused by bile duct stones 2 months prior was admitted to our hospital for removal of the biliary stent and bile duct stones. However, scope insertion into the descending part of the duodenum using a side-viewing endoscope (TJF-260V; Olympus, Tokyo, Japan) during ERCP was difficult because the patient had a cascade stomach that deflected the scope (Fig. 1).
Hence, a large-diameter overtube designed for colonoscopy (ST-CB1; Olympus) was used (Supplementary Video 1). The overtube had a length of 770 mm and outer and inner diameters of 16.2 mm and 13.8 mm, respectively (Fig. 2). We found it better to attach the top hood of the scope to the TJF-260V scope after attaching an overtube. The side-viewing scope with the overtube was easily inserted into the duodenum, as the overtube reduced scope deflection in the stomach (Fig. 3A). After the scope reached the duodenum, it was carefully straightened (Fig. 3B). The biliary stent and bile duct stones were successfully removed without complications.
In conclusion, the large-diameter overtube designed for colonoscopy can be useful for ERCP in patients in whom side-viewing scope insertion into the descending part of the duodenum is difficult due to scope deflection in the stomach.
Supplementary materials related to this article can be found online at https://doi.org/10.5946/ce.2022.089.
Supplementary Video 1. Side-viewing scope insertion using a large-diameter overtube designed for colonoscopy (https://doi.org/10.5946/ce.2022.089.v001).
Fig. 1.
Side-viewing scope insertion into the duodenum during endoscopic retrograde cholangiopancreatography was difficult given the patient’s cascade stomach, which deflected the scope.
ce-2022-089f1.jpg
Fig. 2.
A large-diameter overtube (ST-CB1; Olympus, Tokyo, Japan), which was designed for colonoscopy, had a length of 770 mm and outer and inner diameters of 16.2 mm and 13.8 mm, respectively.
ce-2022-089f2.jpg
Fig. 3.
(A) The overtube reduced the deflection of the scope in the cascade stomach, allowing the side-viewing scope to be easily inserted into the duodenum. (B) After the scope reached the duodenum, the side-viewing scope was carefully straightened.
ce-2022-089f3.jpg
  • 1. Chandrasekhara V, Khashab MA, Muthusamy VR, et al. Adverse events associated with ERCP. Gastrointest Endosc 2017;85:32–47.ArticlePubMed
  • 2. Li G, Chen Y, Zhou X, et al. Early management experience of perforation after ERCP. Gastroenterol Res Pract 2012;2012:657418.ArticlePubMedPMC

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • PubReader PubReader
      • ePub LinkePub Link
      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Side-viewing scope insertion using a large-diameter overtube designed for colonoscopy in a patient with a cascade stomach
        Clin Endosc. 2023;56(2):256-257.   Published online January 5, 2023
        Close
      • XML DownloadXML Download
      Figure
      • 0
      • 1
      • 2
      Side-viewing scope insertion using a large-diameter overtube designed for colonoscopy in a patient with a cascade stomach
      Image Image Image
      Fig. 1. Side-viewing scope insertion into the duodenum during endoscopic retrograde cholangiopancreatography was difficult given the patient’s cascade stomach, which deflected the scope.
      Fig. 2. A large-diameter overtube (ST-CB1; Olympus, Tokyo, Japan), which was designed for colonoscopy, had a length of 770 mm and outer and inner diameters of 16.2 mm and 13.8 mm, respectively.
      Fig. 3. (A) The overtube reduced the deflection of the scope in the cascade stomach, allowing the side-viewing scope to be easily inserted into the duodenum. (B) After the scope reached the duodenum, the side-viewing scope was carefully straightened.
      Side-viewing scope insertion using a large-diameter overtube designed for colonoscopy in a patient with a cascade stomach

      Clin Endosc : Clinical Endoscopy Twitter Facebook
      Close layer
      TOP