Review Single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with surgically altered anatomy: a technical review
Yuki Tanisaka,orcid, Masafumi Mizuideorcid, Akashi Fujitaorcid, Rie Shiomiorcid, Takahiro Shinorcid, Kei Sugimotoorcid, Shomei Ryozawaorcid
Clinical Endoscopy 2023;56(6):716-725.
DOI: https://doi.org/10.5946/ce.2023.023
Published online: April 17, 2023

Department of Gastroenterology, Saitama Medical University International Medical Center, Hidaka, Japan

Correspondence: Yuki Tanisaka Department of Gastroenterology, Saitama Medical University International Medical Center, 1397-1, Yamane, Hidaka, Saitama 350-1298, Japan E-mail: tanisaka1205@gmail.com
• Received: January 4, 2023   • Revised: January 27, 2023   • Accepted: January 28, 2023

Copyright © 2023 Korean Society of Gastrointestinal Endoscopy

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 3,475 Views
  • 360 Download
  • 6 Web of Science
  • 7 Crossref
  • 6 Scopus
prev next
  • Endoscopic retrograde cholangiopancreatography (ERCP) in patients with surgically altered anatomy is technically challenging. For example, scope insertion, selective cannulation, and intended procedures, such as stone extraction or stent placement, can be difficult. Single-balloon enteroscopy (SBE)-assisted ERCP has been used to effectively and safely address these technical issues in clinical practice. However, the small working channel limits its therapeutic potential. To address this shortcoming, a short-type SBE (short SBE) with a working length of 152 cm and a channel of 3.2 mm diameter has recently been introduced. Short SBE facilitates the use of larger accessories to complete certain procedures, such as stone extraction or self-expandable metallic stent placement. Despite the development in the SBE endoscope, various steps have to be overcome to successfully perform such procedure. To improve success, the challenging factors of each procedure must be identified. At the same time, endoscopists need to be mindful of adverse events, such as perforation, which can arise due to adhesions specific to the surgically altered anatomy. This review discussed technical tips regarding SBE-assisted ERCP in patients with surgically altered anatomy to increase success and reduce the risk of adverse events associated with ERCP.
Endoscopic retrograde cholangiopancreatography (ERCP) is a well-established procedure that has been in use for a long time. The success rate of ERCP-related procedures in patients with normal anatomy is 95%.1 In contrast, ERCP in patients with surgically altered anatomy (SAA) is difficult to complete. Patients with SAA includes those who have had a Roux-en-Y gastrectomy (including Roux-en-Y gastric bypass), hepaticojejunostomy with Roux-en-Y (in which all of the stomach is preserved), pancreaticoduodenectomy, and Billroth II gastrectomy. In these patients, various challenges have to be resolved to complete the intended procedure. First, the path to the target site (e.g., papilla or hepaticojejunal anastomosis) is longer compared to normal anatomy, especially for Roux-en-Y anastomosis. Second, selective biliary cannulation in patients with an intact papilla is difficult as the papilla is observed as an inverse image and often located in a tangential direction. Moreover, the completion of selected procedures, such as stone extraction (including endoscopic sphincterotomy [EST]) and self-expandable metallic stent (SEMS) placement, can be exceptionally challenging. In the last two decades, the success rate of selected procedures in patients with SAA, especially those involving the papilla or a hepaticojejunal anastomosis, using conventional endoscopes, such as duodenoscope and pediatric colonoscope, have not been satisfactory.2-4 In failed cases, surgery or percutaneous transhepatic biliary drainage (PTBD) has been necessary.
Double-balloon enteroscopy (DBE) was first introduced clinically in 2001.5 Since then, DBE and single-balloon enteroscopy (SBE)-assisted ERCPs have become the preferable approaches for patients with SAA (Fig. 1A).6-9 Importantly, balloon enteroscopy facilitates scope insertion towards the target site. The latest systematic review and meta-analysis regarding SBE-assisted ERCP reported a pooled total procedure success rate of 75.8%.10 However, the scopes used in SBE-assisted ERCP usually have a working length of 200 cm and a channel of 2.8 mm in diameter and only a few ERCP-accessories have been available. To overcome these limitations, a short-type DBE and SBE (short SBE) with a working length of 152 cm and a channel of 3.2 mm in diameter has been introduced (Fig. 1B). Short SBE can be used with many of accessories needed in procedures, such as stone extraction or SEMS placement.11-13 The reported total procedural success rate of short SBE-assisted ERCP ranged between 70.4% to 85.9% (Table 1).14-17 A recent multi-center study of short SBE-assisted ERCP in patients with SAA reported a total procedural success and adverse event rate of 74.9% and 7.7%, respectively.18 The same study identified several factors associated with procedural failure, including Roux-en-Y anastomosis and malignant cases.18
ERCP in patients with Billroth II gastrectomy is considered possible using the side-viewing and conventional forward-viewing endoscopes. However, there is a reported 10% of scope insertion failure cases using these scopes due to the long and angulated afferent loop. Hence, the use of SBE in difficult cases can provide unique advantages, even in patients with Billroth II gastrectomy.19,20
As more and more endoscopists perform balloon endoscopy (BE)-assisted ERCP, it is important to elucidate technical tips to ensure better outcomes and prevent serious adverse events, such as intestinal perforation. This review discussed the technical tips for performing SBE-assisted ERCP in patients with SAA.
Before inserting the scope, it is important to examine the patient’s past operation record to determine the reconstruction method and access of the afferent limb. In our facility, an attachment cap is placed at the tip of the scope in all cases. This cap facilitates not only scope insertion but also selective biliary cannulation. Importantly, not using the attachment cap is one of the factors attributed to total procedural failure.16 It is also useful to insert the scope under carbon dioxide; otherwise, the room air that accumulates in the small intestine can render insertion difficult. The patients are usually in the prone position to prevent pulmonary aspiration and allow confirmation of the scope position using fluoroscopy.
The principle of deep insertion using SBE is referred to as the “push and pull” method. After pushing the scope pass the corner in the small intestine, the scope is pulled to create pleats that shorten the small intestine. At the time of shortening, the balloon that is attached to the tip of the overtube is advanced. Before performing the shortening, it is better to advance the overtube as deep as possible toward the tip of scope. When advancing the overtube, the balloon should be deflated. While advancing the overtube, the scope tends to also advance, but this is not effective. To overcome this, the scope itself should be pulled while advancing the overtube (Fig. 2 and Supplementary Video 1). When performing the shortening, the balloon is inflated to fix the small intestine and the scope is pulled while the scope angle is used to hook the small intestine. Of note, this is performed without withdrawing the scope. Particularly, the pathway to the target site in patients with hepaticojejunostomy and Roux-en-Y with preserved stomach is long. Therefore, it is important to maximize the scope shortening step. Importantly, scope shortening should be performed right after a loop is made as scope shortening is more difficult if the scope keeps advancing while the loop remained. Immediately after passing through a sharp flexure is an ideal time for scope shortening. It is sometimes difficult to advance the scope when passing through a sharp flexure. Short SBE has a passive bending function which facilitates the smooth passage of the scope through the bend and advance forward.11 Changing the patient to the left lateral position or abdominal compression can effectively facilitate this procedure.
Identifying the afferent limb is one of the next challenges following scope insertion. The way to identify the afferent limb is different depending on the reconstruction method. Distinguishing the junction between the afferent and efferent limbs in patients with Billroth II gastrectomy and pancreaticoduodenectomy (Whipple or Child procedure) is easier than in patients with a Roux-en-Y anastomosis. In the majority of cases, the steep bending part is the afferent limb (Fig. 3A, B). On the other hand, in patients with a Roux-en-Y anastomosis, the anatomy is difficult because the steep bending part is not always the afferent limb. Previous studies have suggested several methods for differentiating the afferent limb, such as confirmation using intraluminal indigo carmine injection or carbon dioxide insufflation at the Roux-en-Y anastomosis.21,22 However, identification can sometimes be difficult even with these methods. To overcome this challenge, we try to confirm the disruption of the transverse folds in patients with Roux-en-Y gastrectomy. As the afferent limb is anastomosed to the side of the slit in Roux-en-Y anastomosis, the site of the disruption can be considered the afferent limb (Fig. 3C).23 In contrast, in patients with hepaticojejunostomy with Roux-en-Y, the transverse folds are symmetric and there is no disruption, thus it is most difficult to identify the afferent limb (Fig. 3D). In such cases, confirming the shape of the scope using fluoroscopy to determine whether the tip of the scope is advancing towards the afferent or efferent limb is necessary.
When inserting the scope to the target site, intestinal perforation from the tight adhesion may arise, especially near the target site. A multi-center study reported intestinal perforation in 1.9% of patients.18 Patients with Billroth II tend to have a short afferent loop between the gastro-jejunal anastomosis and Treitz ligament, which leads to the highest risk of perforation as a strong force is applied to this segment when advancing the scope.24 Careful scope manipulation is required in such cases.
The bile duct is located at 11 to 12 o’clock of the papilla in normal anatomy. On the contrary, it is located at 5 to 6 o’clock in patients with SAA, such as Roux-en-Y gastrectomy or Billroth II gastrectomy, because the papilla is located as an inversed image. Moreover, the method of cannulation is significantly different between DBE and SBE due to the direction of the working channel where the catheter passes through. As the catheter appears from the half past five (05:30) direction in DBE, the positioning and fixing of the papilla at a six o’clock direction on the endoscopic view is considered appropriate. In contrast, as the catheter appears from the eight o’clock direction in SBE, the positioning and fixing of the papilla at eleven o’clock direction is indicated (Fig. 4B).25 Therefore, it is important to control the view of the papilla depending on what type of scope is used for the BE-assisted ERCP. Moreover, as the SBE (also the DBE) has no elevator function, the brand-new straight catheter (without pre-grooming) should be used when performing selective biliary cannulation. The bendable catheter is also useful as it allows the direction of the bile duct to be adjusted.
The papilla is useful for locating the tangential direction of the scope, especially in patients with a Roux-en-Y gastrectomy. In such situations, the retroflex position is useful.26 As the endoscope is advanced, the retroflex position is formed by the up angle of the inferior part of the duodenal angle. As such, the scope makes a J-turn form to provide a better view of the papilla. A good view of the papilla facilitates better success in selective biliary cannulation (Fig. 4). Using multivariate analysis, a previous study determined that the retroflex position increases the likelihood of success in selective biliary cannulation among patients with Roux-en-Y gastrectomy.27 The success rate using the retroflex position is reportedly approximately 60%.24 The success rate depends on the duodenal space and the extent of intestinal adhesion. If forming the retroflex position seems too difficult, it should be omitted, otherwise intestinal perforation may occur.
In cases where selective biliary cannulation is difficult, cannulation using the pancreatic duct, such as the “double-guidewire method”28 may be useful, as this is similar to ERCP in normal anatomy (Fig. 5). Besides the double-guidewire method, pancreatic duct stent-assisted biliary cannulation,29 or cannulation using the double-lumen cannula30 can also be helpful. As selective biliary cannulation in patients with SAA (especially, those with a native papilla) tends to be difficult, many attempts may be required and the longer time involved could cause post-ERCP pancreatitis. Hence, for safety, it is important to abort the procedure after a certain time has lapsed. Rather than prolonging the time, reattempting the cannulation on another day is preferred. Alternatively, the rendezvous technique or direct drainage using an alternative method, such as PTBD or endoscopic ultrasound-guided biliary drainage (EUS-BD), should be considered, depending on the patient’s condition and the procedural details.
Selective biliary cannulation in patients with papilla diversion, such as hepaticojejunal anastomosis (e.g., in patients with hepaticojejunostomy, Roux-en-Y, or pancreaticoduodenectomy) is generally easy as long as the orifice of the hepaticojejunal anastomosis is found. Cannulation failure mostly occurs when the anastomotic site is not reached or found. In cases where the scope has reached the intended location, but the site is difficult to identify, the scar around the orifice can help identify the anastomotic site. Recently, a texture and color enhancement imaging (TXI)-equipped new-generation endoscopy system (EVIS X1; Olympus Marketing)31 has been developed, which facilitates the identification of such orifices.32
After reaching the target site and successful cannulation, the subsequent procedures, such as stone extraction and SEMS placement, can also be challenging. Before performing these procedures, EST, endoscopic papillary balloon dilation, or endoscopic papillary large balloon dilation (EPLBD) is required. Particularly, EST is especially difficult because the cutting direction is usually either opposite to that of standard sphincterotomy or more tangential to that direction. Moreover, there are not many dedicated devices for making a correct incision to the direction of the bile duct safely. Previously, we performed EST using a needle knife after placing a plastic stent in the bile duct to facilitate a safe cutting-direction. The incision is made while exposing the stent and checking that the incision is in the correct direction. Since 2022, we have been performing EST in patients with SAA using a new dedicated sphincterotome (CleverCut3V; KD-V410V-0720; Olympus Marketing).33 The blade of this sphincterotome can be easily adjusted towards the 5 o’clock direction, which indicates the bile duct direction in patients with SAA (Fig. 6).
When performing stone extraction, it is important to loosen the orifice of the papilla as much as possible by performing EST, and/or EPLBD. The main way to control the force for stone extraction in patients with SAA is by withdrawing the scope. However, it is difficult to control the force and intestinal perforation may occur after the scope passes through the papilla if the papilla is not loosened. Therefore, it is highly recommended that the papilla be loosened. Several studies have evaluated the factors affecting complete stone extraction, including the failure to form the retroflex position and a common bile duct diameter of ≥14 mm.34 A larger bile duct diameter (mean, 15.9 mm) has been associated with unsuccessful stone extraction.13 As the SBE has no elevator functions, it is difficult to control the basket catheter in cases with large bile ducts and capturing the stones is also challenging. More dedicated devices for stone extraction in patients with SAA are warranted. When it seems difficult to complete stone extraction via SBE-assisted ERCP, a combination of stone extraction methods, such as adding the EUS-BD route, may be a good alternative.35,36
As the short SBE has a working channel diameter of 3.2 mm, it makes possible to place various SEMS in patients with SAA.34 Almost all SEMSs used in patients with normal anatomy can also be used for patients with SAA. However, some SEMSs have a length of approximately 180 cm, so it is impossible to place them into the hilar part across the stricture, especially in patients with a papilla and a common bile duct. On the other hand, SEMSs with a working length of 180 cm can be placed into the hilar part in patients with hepaticojejunal anastomosis (hepaticojejunostomy with Roux-en-Y or pancreaticoduodenectomy) whose common bile duct has been resected. Therefore, a SEMS with enough length to access the intended area is important. This is dependent on the anatomy when performing ERCP in patients with SAA using a short SBE. We usually place a covered SEMS in patients with distal malignant biliary obstruction across the papilla after performing an EST and an uncovered SEMS in patients with hilar malignant biliary obstruction (Fig. 7). The clinical success and recurrent biliary obstruction rates in patients with SAA were similar to those in normal anatomy using SEMS.37,38 In recurrent biliary obstruction, the papilla or hepaticojejunal anastomosis is located in the deep afferent limb, thus, it is assumed that food impaction rarely occurs in patients with SAA compared to normal anatomy.37 However, afferent limb obstruction may cause recurrent biliary obstruction while the stent is still patent.
It is important to be aware of factors that may lead to incomplete SBE-assisted ERCP procedures. Several reports have evaluated these factors.16-18 In particular, Roux-en-Y reconstruction, malignant biliary obstruction, and pancreatic indications were identified.
Appropriate responses to such difficult situations is paramount. First, in cases of Roux-en-Y, the difficulty associated with scope insertion increases the failure risk. In patients with Roux-en-Y gastric bypass and hepaticojejunostomy with Roux-en-Y, the longer Roux limbs contribute to the difficulty. In such cases, conventional SBE with a working length of 200 cm is useful. We use the 200 cm scope when scope insertion using the short SBE failed. A previous study of 27 patients with scope insertion failure using short SBE reported that 24 (88.9%) succeeded with a conventional SBE.18 Second, malignant biliary obstruction cases tend to cause strong adhesion due to cancer, so scope manipulation is difficult and procedural failure is possible. Moreover, small intestine or papilla invasion due to the cancer may further complicate the procedure. In such cases, it is difficult to complete the intended procedure by SBE-assisted ERCP. PTBD or EUS-BD could be good alternatives. Third, pancreatic indications, especially when approaching the pancreaticojejunal anastomosis, are difficult as a pancreatico-jejunal anastomosis is located deeper than a hepaticojejunal anastomosis in the afferent limb, thus, more difficult to find, especially in instances of complete obstruction. The technical success rate in these cases is approximately 70%.39 As mentioned above, the TXI-equipped new-generation endoscopy system can facilitate the identification of such orifices.32 Furthermore, the EUS-guided pancreatic duct approach should be considered, although this procedure is more difficult and may cause more severe adverse events, compared to EUS-BD procedures.
In the present review, we discussed the technical tips of SBE-assisted ERCP in terms of scope insertion, selective biliary cannulation, and subsequent procedures and highlighted points for the prevention of adverse events. The study also reported on the factors that affect procedural success and the strategies for solving these difficulties. The review aimed to inform endoscopists who are performing SBE-assisted ERCP. Recently, EUS-BD has been reported as another alternative with a shorter procedure duration. However, due to the limited accessory choices, EUS-BD may cause severe adverse events, such as bile leak or stent migration into the abdominal cavity, even when performed by experienced endoscopists. In contrast, DBE- and SBE-assisted ERCPs are more predictable and safer because ERCP is a well-established procedure and many dedicated accessories are available. Furthermore, when choosing between SBE-assisted ERCP or EUS-BD, the postoperative reconstruction, patient condition, and more importantly, the endoscopist’s experience should be considered.

Supplementary Video 1.

The way to advance an overtube. Scope itself should be pulled while advancing the overtube (https://doi.org/10.5946/ce-2023-023.v1).
Supplementary materials related to this article can be found online at https://doi.org/10.5946/ce.2023.023.
Fig. 1.
Single-balloon enteroscopy (SBE). (A) A conventional SBE with a 200 cm working length and a 2.8 mm working channel in diameter. (B) A short SBE with a 152 cm working length and a 3.2 mm working channel in diameter.
ce-2023-023f1.jpg
Fig. 2.
The way to advance an overtube. Scope itself should be pulled (red arrow) while advancing the overtube (pink arrow).
ce-2023-023f2.jpg
Fig. 3.
Endoscopic findings. (A) A patient with Billroth II gastrectomy. The steep bending part is ordinarily the afferent limb (arrow). (B) A patient with pancreaticoduodenectomy (Child procedure). The steep bending part is ordinarily the afferent limb (arrow). (C) A patient with Roux-en-Y gastrectomy. The disruption of the transverse folds is seen, therefore the slit die of the afferent limb (arrow). (D) A hepaticojejunostomy with Roux-en-Y. There is uncertain whether it is an afferent limb or not.
ce-2023-023f3.jpg
Fig. 4.
The retroflex position. (A, C) The papilla is positioned tangentially so it is difficult to perform selective biliary cannulation. (B, D) The scope is advanced while using the up-angle at the inferior duodenal angle, and adjusts to the retroflex position. Consequently, a better view of the papilla can be obtained.
ce-2023-023f4.jpg
Fig. 5.
Selective biliary cannulation using the double-guidewire method. (A, B) Pancreatic duct cannulation is performed and a guidewire is placed in the pancreatic duct. (C, D) As the bile and pancreatic duct are separated well using this method, selective biliary cannulation is achieved.
ce-2023-023f5.jpg
Fig. 6.
Endoscopic sphincterotomy (EST) using a dedicated sphincterotomy for patients with surgically altered anatomy. (A) The blade can be easily adjusted towards the 5 o’clock direction, which indicates the bile duct direction in patients with surgically altered anatomy. (B) Successful EST is achieved.
ce-2023-023f6.jpg
Fig. 7.
Self-expandable metallic stent (SEMS) placement in patients with surgically altered anatomy. (A–C) A patient with distal malignant biliary obstruction. Covered SEMS is placed across the papilla. (D–F) A patient with hilar malignant biliary obstruction. Two uncovered SEMS (partial stent in stent method) are placed.
ce-2023-023f7.jpg
Table 1.
Outcomes of short single-balloon enteroscopy-assisted ERCP in patients with surgically altered anatomy
Study Year Category Enteroscopy success Cannulation success Total procedural success
Shimatani et al.14 2014 Total 92.3 (24/26) 91.7 (22/24) 84.6 (22/26)
RYG 100 (4/4) 75.0 (3/4) 75.0 (3/4)
HJRY 75.0 (6/8) 100 (6/6) 75.0 (6/8)
PD 100 (9/9) 100 (9/9) 100 (9/9)
B-II 100 (3/3) 100 (3/3) 100 (3/3)
Others 100 (2/2) 50.0 (1/2) 50.0 (1/2)
Kawamura et al.15 2015 Total 88.9 (24/27) 83.3 (20/24) 70.4 (19/27)
RYG 86.7 (13/15) 76.9 (10/13) 60.0 (9/15)
HJRY 90.0 (9/10) 100 (9/9) 90.0 (9/10)
B-II 100 (2/2) 50.0 (1/2) 50.0 (1/2)
Yane et al.16 2017 Total 92.6 (188/203) N/A 81.8 (166/203)
RYG 95.6 (43/45) 88.9 (40/45)
HJRY 81.4 (48/59) 79.7 (47/59)
PD 97.5 (77/79) 75.9 (60/79)
B-II 100 (20/20) 95.0 (19/20)
Tanisaka et al.17 2019 Total 94.8 (181/191) 92.3 (167/181) 85.9 (164/191)
RYG 93.1 (81/87) 85.2 (69/81) 75.9 (66/87)
HJRY 88.2 (30/34) 96.7 (29/30) 85.3 (29/34)
PD 100 (39/39) 97.4 (38/39) 97.4 (38/39)
B-II 100 (31/31) 100 (31/31) 100 (31/31)

Values are presented as % (number/total number).

ERCP, endoscopic retrograde cholangiopancreatography; RYG, Roux-en-Y gastrectomy; HJRY, hepaticojejunostomy with Roux-en-Y; PD, pancreaticoduodenectomy; B-II, Billroth II gastrectomy; N/A, not available.

  • 1. Freeman ML, Guda NM. ERCP cannulation: a review of reported techniques. Gastrointest Endosc 2005;61:112–125.ArticlePubMed
  • 2. Hintze RE, Adler A, Veltzke W, et al. Endoscopic access to the papilla of Vater for endoscopic retrograde cholangiopancreatography in patients with Billroth II or Roux-en-Y gastrojejunostomy. Endoscopy 1997;29:69–73.ArticlePubMed
  • 3. Elton E, Hanson BL, Qaseem T, et al. Diagnostic and therapeutic ERCP using an enteroscope and a pediatric colonoscope in long-limb surgical bypass patients. Gastrointest Endosc 1998;47:62–67.ArticlePubMed
  • 4. Wright BE, Cass OW, Freeman ML. ERCP in patients with long-limb Roux-en-Y gastrojejunostomy and intact papilla. Gastrointest Endosc 2002;56:225–232.ArticlePubMed
  • 5. Yamamoto H, Sekine Y, Sato Y, et al. Total enteroscopy with a nonsurgical steerable double-balloon method. Gastrointest Endosc 2001;53:216–220.ArticlePubMed
  • 6. Aabakken L, Bretthauer M, Line PD. Double-balloon enteroscopy for endoscopic retrograde cholangiography in patients with a Roux-en-Y anastomosis. Endoscopy 2007;39:1068–1071.ArticlePubMed
  • 7. Emmett DS, Mallat DB. Double-balloon ERCP in patients who have undergone Roux-en-Y surgery: a case series. Gastrointest Endosc 2007;66:1038–1041.ArticlePubMed
  • 8. Itoi T, Ishii K, Sofuni A, et al. Single-balloon enteroscopy-assisted ERCP in patients with Billroth II gastrectomy or Roux-en-Y anastomosis (with video). Am J Gastroenterol 2010;105:93–99.ArticlePubMedPDF
  • 9. Wang AY, Sauer BG, Behm BW, et al. Single-balloon enteroscopy effectively enables diagnostic and therapeutic retrograde cholangiography in patients with surgically altered anatomy. Gastrointest Endosc 2010;71:641–649.ArticlePubMed
  • 10. Tanisaka Y, Ryozawa S, Mizuide M, et al. Status of single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with surgically altered anatomy: systematic review and meta-analysis on biliary interventions. Dig Endosc 2021;33:1034–1044.ArticlePubMedPDF
  • 11. Tanisaka Y, Ryozawa S, Mizuide M, et al. Usefulness of the “newly designed” short-type single-balloon enteroscope for ERCP in patients with Roux-en-Y gastrectomy: a pilot study. Endosc Int Open 2018;6:E1417–E1422.ArticlePubMedPMC
  • 12. Tanisaka Y, Mizuide M, Fujita A, et al. Competence development of trainees performing short-type single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with surgically altered anatomy. J Hepatobiliary Pancreat Sci 2022;29:1316–1326.ArticlePubMedPDF
  • 13. Tanisaka Y, Mizuide M, Fujita A, et al. Factors affecting complete stone extraction in the initial procedure in short type single-balloon enteroscopy-assisted endoscopic retrograde cholangiography for patients with Roux-en-Y gastrectomy. Scand J Gastroenterol 2022;57:1390–1396.ArticlePubMed
  • 14. Shimatani M, Takaoka M, Ikeura T, et al. Evaluation of endoscopic retrograde cholangiopancreatography using a newly developed short-type single-balloon endoscope in patients with altered gastrointestinal anatomy. Dig Endosc 2014;26 Suppl 2:147–155.ArticlePubMed
  • 15. Kawamura T, Uno K, Suzuki A, et al. Clinical usefulness of a short-type, prototype single-balloon enteroscope for endoscopic retrograde cholangiopancreatography in patients with altered gastrointestinal anatomy: preliminary experiences. Dig Endosc 2015;27:82–86.ArticlePubMed
  • 16. Yane K, Katanuma A, Maguchi H, et al. Short-type single-balloon enteroscope-assisted ERCP in postsurgical altered anatomy: potential factors affecting procedural failure. Endoscopy 2017;49:69–74.ArticlePubMed
  • 17. Tanisaka Y, Ryozawa S, Mizuide M, et al. Analysis of the factors involved in procedural failure: endoscopic retrograde cholangiopancreatography using a short-type single-balloon enteroscope for patients with surgically altered gastrointestinal anatomy. Dig Endosc 2019;31:682–689.ArticlePubMedPDF
  • 18. Tanisaka Y, Ryozawa S, Itoi T, et al. Efficacy and factors affecting procedure results of short-type single-balloon enteroscopy-assisted ERCP for altered anatomy: a multicenter cohort in Japan. Gastrointest Endosc 2022;95:310–318.ArticlePubMed
  • 19. Zhu F, Guan Y, Wang J. Efficacy and safety of the rotatable sphincterotome during ERCP in patients with prior Billroth II gastrectomy (with videos). Surg Endosc 2021;35:4849–4856.ArticlePubMedPDF
  • 20. Park TY, Bang CS, Choi SH, et al. Forward-viewing endoscope for ERCP in patients with Billroth II gastrectomy: a systematic review and meta-analysis. Surg Endosc 2018;32:4598–4613.ArticlePubMedPDF
  • 21. Yano T, Hatanaka H, Yamamoto H, et al. Intraluminal injection of indigo carmine facilitates identification of the afferent limb during double-balloon ERCP. Endoscopy 2012;44 Suppl 2 UCTN:E340–E341.ArticlePubMed
  • 22. Iwai T, Kida M, Yamauchi H, et al. Short-type and conventional single-balloon enteroscopes for endoscopic retrograde cholangiopancreatography in patients with surgically altered anatomy: single-center experience. Dig Endosc 2014;26 Suppl 2:156–163.ArticlePubMed
  • 23. Kanno Y, Ohira T, Kozakai F, et al. Accurate endoscopic identification of the afferent limb at the Y anastomosis using the fold disruption sign after gastric resection with Roux-en-Y reconstruction. Dig Endosc 2022;34:238–243.ArticlePubMedPDF
  • 24. Tokuhara M, Shimatani M, Mitsuyama T, et al. Evaluation of complications after endoscopic retrograde cholangiopancreatography using a short type double balloon endoscope in patients with altered gastrointestinal anatomy: a single-center retrospective study of 1,576 procedures. J Gastroenterol Hepatol 2020;35:1387–1396.ArticlePubMedPDF
  • 25. Yang MJ, Hwang JC, Yoo BM, et al. Balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography. Korean J Pancreas Biliary Tract 2021;26:205–208.ArticlePDF
  • 26. Ishii K, Itoi T, Tonozuka R, et al. Balloon enteroscopy-assisted ERCP in patients with Roux-en-Y gastrectomy and intact papillae (with videos). Gastrointest Endosc 2016;83:377–386.ArticlePubMed
  • 27. Tanisaka Y, Ryozawa S, Mizuide M, et al. Biliary cannulation in patients with Roux-en-Y gastrectomy: an analysis of the factors associated with successful cannulation. Intern Med 2020;59:1687–1693.ArticlePubMedPMC
  • 28. Ito K, Horaguchi J, Fujita N, et al. Clinical usefulness of double-guidewire technique for difficult biliary cannulation in endoscopic retrograde cholangiopancreatography. Dig Endosc 2014;26:442–449.ArticlePubMedPDF
  • 29. Tanisaka Y, Ryozawa S, Mizuide M, et al. Novel technique using pancreatic duct stent facilitates difficult biliary cannulation in patients with Roux-en-Y anatomy (with video). JGH Open 2019;4:296–298.ArticlePubMedPMCPDF
  • 30. Takenaka M, Minaga K, Kamata K, et al. Efficacy of a modified double-guidewire technique using an uneven double lumen cannula (uneven method) in patients with surgically altered gastrointestinal anatomy (with video). Surg Endosc 2020;34:1432–1441.ArticlePubMedPDF
  • 31. Sato T. TXI: texture and color enhancement imaging for endoscopic image enhancement. J Healthc Eng 2021;2021:5518948.ArticlePubMedPMCPDF
  • 32. Tanisaka Y, Mizuide M, Fujita A, et al. Use of texture and color enhancement imaging to identify the pancreatic duct orifice in a patient with a pancreaticojejunal anastomotic stricture. Endoscopy 2023;55(S 01):E88–E89.ArticlePubMed
  • 33. Tanisaka Y, Mizuide M, Fujita A, et al. A novel sphincterotome facilitates endoscopic sphincterotomy in patients with Roux-en-Y gastrectomy. Endoscopy 2022;54(S 02):E780–E781.ArticlePubMedPMC
  • 34. Obata T, Tsutsumi K, Kato H, et al. Balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography for the treatment of common bile duct stones in patients with Roux-en-Y gastrectomy: outcomes and factors affecting complete stone extraction. J Clin Med 2021;10:3314.ArticlePubMedPMC
  • 35. Iwashita T, Nakai Y, Hara K, et al. Endoscopic ultrasound-guided antegrade treatment of bile duct stone in patients with surgically altered anatomy: a multicenter retrospective cohort study. J Hepatobiliary Pancreat Sci 2016;23:227–233.ArticlePubMed
  • 36. Ogura T, Kawai J, Nishiguchi K, et al. Transluminal intrahepatic bile duct stone removal using a novel spiral basket catheter via the endoscopic ultrasound-guided hepaticogastrostomy route (with video). Dig Endosc 2022;34:234–237.ArticlePubMedPDF
  • 37. Tanisaka Y, Ryozawa S, Mizuide M, et al. Usefulness of self-expandable metal stents for malignant biliary obstruction using a short-type single-balloon enteroscope in patients with surgically altered anatomy. J Hepatobiliary Pancreat Sci 2021;28:272–279.ArticlePubMedPDF
  • 38. Takeda T, Sasaki T, Mie T, et al. The safety and efficacy of self-expandable metallic stent placement for malignant biliary obstruction with surgically altered anatomy. Scand J Gastroenterol 2021;56:94–102.ArticlePubMed
  • 39. Kogure H, Sato T, Nakai Y, et al. Endoscopic management of pancreatic diseases in patients with surgically altered anatomy: clinical outcomes of combination of double-balloon endoscopy- and endoscopic ultrasound-guided interventions. Dig Endosc 2021;33:441–450.ArticlePubMedPDF

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  
    • Advanced technical tips and recent insights in ERCP using balloon‐assisted endoscopy
      Masaaki Shimatani, Toshiyuki Mitsuyama, Takeshi Yamashina, Masahiro Takeo, Shunsuke Horitani, Natsuko Saito, Hironao Matsumoto, Masahiro Orino, Masataka Kano, Takafumi Yuba, Takuya Takayama, Tatsuya Nakagawa, Shoji Takayama
      DEN Open.2024;[Epub]     CrossRef
    • Efficacy of texture and color enhancement imaging for short‐type single‐balloon enteroscopy‐assisted biliary cannulation in patients with Roux‐en‐Y gastrectomy: Multicenter study (with video)
      Yuki Tanisaka, Mamoru Takenaka, Masafumi Mizuide, Akashi Fujita, Ryuhei Jinushi, Takahiro Shin, Kei Sugimoto, Ken Kamata, Kosuke Minaga, Shunsuke Omoto, Tomohiro Yamazaki, Shomei Ryozawa
      Digestive Endoscopy.2024; 36(9): 1030.     CrossRef
    • Progress in minimally invasive treatment of biliary pancreatic duct obstruction after digestive tract reconstruction by endoscopic retrograde cholangiopancreatography
      Ru-Yi Wang, Zhen Fan
      World Chinese Journal of Digestology.2024; 32(7): 490.     CrossRef
    • Endoscopic Management of Biliary and Pancreatic Pathologies in Roux-en-Y Gastric Bypass Patients: Development of a Treatment Algorithm Based on 9-Year Experience
      Laurent Monino, Lancelot Marique, Yannick Deswysen, Maximilien Thoma, Pierre H. Deprez, Pierre Goffette, Benoit Navez, Tom G. Moreels
      Obesity Surgery.2024; 34(10): 3717.     CrossRef
    • Use of short single-balloon enteroscopy in patients with surgically altered anatomy: a single-center experience
      Songming Ding, Shanjie Dong, Hengkai Zhu, Yiting Hu, Shusen Zheng, Qiyong Li
      Scientific Reports.2024;[Epub]     CrossRef
    • Development and evaluation of artificial organ models for ERCP training in patients with surgically altered anatomies
      Kai Koch, Benedikt Duckworth-Mothes, Ulrich Schweizer, Karl-Ernst Grund, Tom G. Moreels, Alfred Königsrainer, Dörte Wichmann
      Scientific Reports.2023;[Epub]     CrossRef
    • Simplified single-session EUS-guided transhepatic antegrade stone removal for management of choledocholithiasis in patients with surgically altered anatomy
      Tingting Yu, Suning Hou, Haiming Du, Wei Zhang, Jiao Tian, Yankun Hou, Jun Yao, Senlin Hou, Lichao Zhang
      Gastroenterology Report.2023;[Epub]     CrossRef

    • PubReader PubReader
    • ePub LinkePub Link
    • Cite
      CITE
      export Copy Download
      Close
      Download Citation
      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:
      • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
      • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
      Include:
      • Citation for the content below
      Single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with surgically altered anatomy: a technical review
      Clin Endosc. 2023;56(6):716-725.   Published online April 17, 2023
      Close
    • XML DownloadXML Download
    Figure
    • 0
    • 1
    • 2
    • 3
    • 4
    • 5
    • 6
    Related articles
    Single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with surgically altered anatomy: a technical review
    Image Image Image Image Image Image Image
    Fig. 1. Single-balloon enteroscopy (SBE). (A) A conventional SBE with a 200 cm working length and a 2.8 mm working channel in diameter. (B) A short SBE with a 152 cm working length and a 3.2 mm working channel in diameter.
    Fig. 2. The way to advance an overtube. Scope itself should be pulled (red arrow) while advancing the overtube (pink arrow).
    Fig. 3. Endoscopic findings. (A) A patient with Billroth II gastrectomy. The steep bending part is ordinarily the afferent limb (arrow). (B) A patient with pancreaticoduodenectomy (Child procedure). The steep bending part is ordinarily the afferent limb (arrow). (C) A patient with Roux-en-Y gastrectomy. The disruption of the transverse folds is seen, therefore the slit die of the afferent limb (arrow). (D) A hepaticojejunostomy with Roux-en-Y. There is uncertain whether it is an afferent limb or not.
    Fig. 4. The retroflex position. (A, C) The papilla is positioned tangentially so it is difficult to perform selective biliary cannulation. (B, D) The scope is advanced while using the up-angle at the inferior duodenal angle, and adjusts to the retroflex position. Consequently, a better view of the papilla can be obtained.
    Fig. 5. Selective biliary cannulation using the double-guidewire method. (A, B) Pancreatic duct cannulation is performed and a guidewire is placed in the pancreatic duct. (C, D) As the bile and pancreatic duct are separated well using this method, selective biliary cannulation is achieved.
    Fig. 6. Endoscopic sphincterotomy (EST) using a dedicated sphincterotomy for patients with surgically altered anatomy. (A) The blade can be easily adjusted towards the 5 o’clock direction, which indicates the bile duct direction in patients with surgically altered anatomy. (B) Successful EST is achieved.
    Fig. 7. Self-expandable metallic stent (SEMS) placement in patients with surgically altered anatomy. (A–C) A patient with distal malignant biliary obstruction. Covered SEMS is placed across the papilla. (D–F) A patient with hilar malignant biliary obstruction. Two uncovered SEMS (partial stent in stent method) are placed.
    Single-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with surgically altered anatomy: a technical review
    Study Year Category Enteroscopy success Cannulation success Total procedural success
    Shimatani et al.14 2014 Total 92.3 (24/26) 91.7 (22/24) 84.6 (22/26)
    RYG 100 (4/4) 75.0 (3/4) 75.0 (3/4)
    HJRY 75.0 (6/8) 100 (6/6) 75.0 (6/8)
    PD 100 (9/9) 100 (9/9) 100 (9/9)
    B-II 100 (3/3) 100 (3/3) 100 (3/3)
    Others 100 (2/2) 50.0 (1/2) 50.0 (1/2)
    Kawamura et al.15 2015 Total 88.9 (24/27) 83.3 (20/24) 70.4 (19/27)
    RYG 86.7 (13/15) 76.9 (10/13) 60.0 (9/15)
    HJRY 90.0 (9/10) 100 (9/9) 90.0 (9/10)
    B-II 100 (2/2) 50.0 (1/2) 50.0 (1/2)
    Yane et al.16 2017 Total 92.6 (188/203) N/A 81.8 (166/203)
    RYG 95.6 (43/45) 88.9 (40/45)
    HJRY 81.4 (48/59) 79.7 (47/59)
    PD 97.5 (77/79) 75.9 (60/79)
    B-II 100 (20/20) 95.0 (19/20)
    Tanisaka et al.17 2019 Total 94.8 (181/191) 92.3 (167/181) 85.9 (164/191)
    RYG 93.1 (81/87) 85.2 (69/81) 75.9 (66/87)
    HJRY 88.2 (30/34) 96.7 (29/30) 85.3 (29/34)
    PD 100 (39/39) 97.4 (38/39) 97.4 (38/39)
    B-II 100 (31/31) 100 (31/31) 100 (31/31)
    Table 1. Outcomes of short single-balloon enteroscopy-assisted ERCP in patients with surgically altered anatomy

    Values are presented as % (number/total number).

    ERCP, endoscopic retrograde cholangiopancreatography; RYG, Roux-en-Y gastrectomy; HJRY, hepaticojejunostomy with Roux-en-Y; PD, pancreaticoduodenectomy; B-II, Billroth II gastrectomy; N/A, not available.


    Clin Endosc : Clinical Endoscopy Twitter Facebook