1Department of Gastroenterology, International University of Health and Welfare Ichikawa Hospital, Chiba, Japan
2Department of Gastrointestinal Endoscopy, NTT Medical Center Tokyo, Tokyo, Japan
Copyright © 2023 Korean Society of Gastrointestinal Endoscopy
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
IEE | Company | Release year | Feature |
---|---|---|---|
NBI | Olympus Corporation | 2006 | NBI emphasizes the microstructure and capillaries on the mucosal surface by modifying the center wavelength and bandwidth of a light into narrow-band illumination at 415±30 nm within the hemoglobin absorption band. |
TXI | Olympus Corporation | 2020 | TXI has two modes in terms of enhancement factors: TXI mode 1 (texture, brightness, and color enhancement) and TXI mode 2 (texture and brightness enhancement). Under TXI mode 1, the color contrast between red and white is greater than in mode 2, and the reddish mucosa appears redder. TXI mode 2 produces images that are closer to the WLE color tone. |
BLI | Fujifilm Corporation | 2012 | BLI use a 410 nm narrow-band wavelength to contrast hemoglobin and visualize high-contrast mucosal superficial vessels and structures. |
“BLI-bright” mode provides brighter images than BLI mode. | |||
LCI | Fujifilm Corporation | 2012 | LCI provides a better visibility score and significant color difference between the lesion and surrounding mucosa by separating the red color to enhance slight color difference in the mucosal membrane. |
I-scan | Pentax Corporation | 2007 | I-scan has four modes of image enhancement (SE, CE, TE, and OE). The OE has two modes (mode 1 and mode 2). The OE mode 1 improves visualization of surface microvessels, and the OE mode 2 improves contrast of white-light observation by bringing the color tone. |
Study | IEE modality | Design | Subject numbers | ADR |
PDR |
||||
---|---|---|---|---|---|---|---|---|---|
IEE (%) | WLE (%) | Relative risk | IEE (%) | WLE (%) | Relative risk | ||||
Atkinson et al. (2019)20 | NBI | Meta-analysis | 4,491 | 45.2 | 42.3 | 1.07 |
56.9 | 53.9 | 1.06 |
Sakamoto et al. (2023)21 | TXI | Retrospective | 470 | 58.2 | 46.8 | 1.24 |
80.2 | 63.9 | 1.25 |
Ikematsu et al. (2017)22 | BLI | RCT | 963 | 54.8 | 52.7 | 1.04 |
68.3 | 62.4 | 1.09 |
Suzuki et al. (2023)23 | LCI | RCT | 3,050 | 58.7 | 46.7 | 1.26 | 68.6 | 59.5 | 1.15 |
Aziz et al. (2022)24 | I-scan | Meta-analysis | 2,620 | 43.4 | 39.7 | 1.20 | 51.7 | 53.9 | 1.08 |
NBI, narrow-band imaging; TXI, texture and color enhancement imaging; BLI, blue laser imaging/blue light imaging; LCI, linked color imaging; SE, surface enhancement; CE, contrast enhancement; TE, tone enhancement; OE, optical enhancement.
IEE, image-enhanced endoscopy; WLE, white light endoscopy; ADR, adenoma detection rate; PDR, polyp detection rate; NBI, narrow-band imaging; TXI, texture and color enhancement imaging; BLI, blue laser imaging/blue light imaging; LCI, linked color imaging; RCT, randomized controlled trial. Values were calculated on the basis of the original data.