Skip Navigation
Skip to contents

Clin Endosc : Clinical Endoscopy

OPEN ACCESS

Articles

Page Path
HOME > Clin Endosc > Volume 57(3); 2024 > Article
Image of Issue Aortoduodenal fistula bleeding caused by an aortic stent graft
Seunghyun Hongorcid, Gwang Ha Kim,orcid
Clinical Endoscopy 2024;57(3):407-408.
DOI: https://doi.org/10.5946/ce.2023.281
Published online: February 2, 2024

Department of Internal Medicine, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Hospital, Busan, Korea

Correspondence: Gwang Ha Kim Department of Internal Medicine, Pusan National University School of Medicine and Biomedical Research Institute, Pusan National University Hospital, 179 Gudeok-ro, Seo-gu, Busan 49241, Korea E-mail: doc0224@pusan.ac.kr
• Received: November 4, 2023   • Revised: November 29, 2023   • Accepted: November 30, 2023

© 2024 Korean Society of Gastrointestinal Endoscopy

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 2,604 Views
  • 178 Download
  • 1 Web of Science
prev next
A 65-year-old female visited the emergency room due to sudden hematemesis and hematochezia. One year earlier, the patient underwent endovascular implantation of an aorto-bi-iliac bifurcation stent graft for a fusiform infrarenal aortic aneurysm that extended to the left common iliac artery. At the time of presentation, her blood pressure and heart rate were 70/40 mmHg and 105 beats/min, respectively. Laboratory findings showed a white blood cell count of 13,000/μL, hemoglobin level of 8.0 g/dL, and platelet count of 405,000/μL. Emergent endoscopy identified a foreign material (an aortic stent graft) with vascular pulsation in the third part of the duodenum (Fig. 1). Abdominal computed tomography revealed increased fat stranding around the aorta, which is indicative of inflammation, and a loss of the fat plane between the duodenum and aorta (Fig. 2). Therefore, the cause of bleeding was diagnosed as an aortoduodenal fistula caused by the previously placed aortic stent graft. The patient underwent primary closure of the duodenal perforation and omental wrapping and was discharged without any complications. However, the patient passed away 31 months later due to recurrence of the aortoduodenal fistula.
Aortoenteric fistula can occur secondary to aortic reconstruction procedures1 and can develop anywhere in the gastrointestinal tract adjacent to the aorta; however, it is most frequently observed in the third part of the duodenum, which is anchored in the retroperitoneal space and positioned directly anterior to the aorta. The location of the duodenum in close proximity to the aorta makes it susceptible to fistula formation due to the constant transmission of pulsatile forces from the aorta.2 Therefore, aortoduodenal fistula should be considered a potential cause of hematemesis or hematochezia in patients with a history of aortic stent graft.3
Fig. 1.
Upper gastrointestinal endoscopy reveals a foreign material (an aortic stent graft) and blood clot with vascular pulsation (asterisk) in the third part of the duodenum.
ce-2023-281f1.jpg
Fig. 2.
Abdominal computed tomography reveals increased fat stranding around the aorta, which is indicative of inflammation, and a loss of the fat plane between the duodenum and aorta (arrows). (A) Pre-enhanced phase. (B) Arterial phase.
ce-2023-281f2.jpg
  • 1. Kim BY, Kim KB. Primary aortoduodenal fistula causes massive melena: a case report. Korean J Gastroenterol 2021;77:132–135.ArticlePubMed
  • 2. Janne d'Othée B, Soula P, Otal P, et al. Aortoduodenal fistula after endovascular stent-graft of an abdominal aortic aneurysm. J Vasc Surg 2000;31:190–195.ArticlePubMed
  • 3. Kim SE, Kim HJ, Koh M, et al. A practical approach for small bowel bleeding. Clin Endosc 2023;56:283–289.ArticlePubMedPMCPDF

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • PubReader PubReader
      • ePub LinkePub Link
      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Aortoduodenal fistula bleeding caused by an aortic stent graft
        Clin Endosc. 2024;57(3):407-408.   Published online February 2, 2024
        Close
      • XML DownloadXML Download
      Figure
      • 0
      • 1
      Aortoduodenal fistula bleeding caused by an aortic stent graft
      Image Image
      Fig. 1. Upper gastrointestinal endoscopy reveals a foreign material (an aortic stent graft) and blood clot with vascular pulsation (asterisk) in the third part of the duodenum.
      Fig. 2. Abdominal computed tomography reveals increased fat stranding around the aorta, which is indicative of inflammation, and a loss of the fat plane between the duodenum and aorta (arrows). (A) Pre-enhanced phase. (B) Arterial phase.
      Aortoduodenal fistula bleeding caused by an aortic stent graft

      Clin Endosc : Clinical Endoscopy Twitter Facebook
      Close layer
      TOP