Skip Navigation
Skip to contents

Clin Endosc : Clinical Endoscopy

OPEN ACCESS

Articles

Page Path
HOME > Clin Endosc > Volume 59(3); 2026 > Article
Video of Issue Mucosal defect closure using the side hole of a transparent hood
Yasuhiro Taniguchi1orcid, Takuma Okamura2orcid, Hisamitsu Miyaaki3orcid
Clinical Endoscopy 2026;59(3):470-471.
DOI: https://doi.org/10.5946/ce.2025.183
Published online: August 18, 2025

1Department of Gastroenterology, Sasebo City General Hospital, Nagasaki, Japan

2Department of Gastroenterology, Nagasaki Harbor Medical Center, Nagasaki, Japan

3Department of Gastroenterology and Hepatology, Nagasaki University, Nagasaki, Japan

Correspondence: Yasuhiro Taniguchi Department of Gastroenterology, Sasebo City General Hospital, 9-3 Hirase-cho, Sasebo, Nagasaki 857-8511, Japan E-mail: ytaniguchi1989@hotmail.com
• Received: June 5, 2025   • Revised: June 22, 2025   • Accepted: June 23, 2025

© 2026 Korean Society of Gastrointestinal Endoscopy

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 2,682 Views
  • 166 Download
prev next
Mucosal defect closure following endoscopic submucosal dissection (ESD) is crucial in preventing complications such as bleeding and perforation.1 Many existing techniques, including endoloop-assisted methods, over-the-scope clips, and suture-based approaches, require specialized devices, dual-channel endoscopes, or advanced technical skills. Therefore, we developed a side-hole method (SHM) that uses the side hole of a transparent hood for endoscopic mucosal defect closure.
We performed SHM in an 84-year-old man with a 13-mm, 0-IIa-type early gastric cancer located on the greater curvature of the gastric angle. ESD achieved en bloc resection, resulting in a 38 mm×35 mm mucosal defect. Closure was performed using a single-channel endoscope (GIF-H290T; Olympus) with a transparent hood (D-201-11804; Olympus). A 2-0 absorbable suture thread (Elmelt; Akiyama Medical) was affixed to the arm of an EZ clip (HX610-090SC; Olympus) and passed through the side hole of the hood (Fig. 1). The side hole was aligned with the defect at the 6 o’clock position on the endoscopic screen to optimize the directionality. With the hood positioned, the first clip was deployed at the anal edge. Additional clips were applied along the margins while each clip was threaded. Upon placement of all clips, the thread was pulled externally to approximate the mucosal edges. The remaining thread was cut with a scissor device (FS-3L-1; Olympus). Closure was completed within 19 minutes using 20 clips (Fig. 2, Video 1).
SHM, adapted from the string suture2 and reopenable-clip over the line3 methods, uniquely leverages the side hole of a transparent hood. It enables external thread manipulation, which minimizes channel interference and simplifies the procedure, and is cost-effective, employing standard EZ clips that are relatively inexpensive (approximately 1,000 JPY/clip). This technique does not require specialized equipment or a dual-channel endoscope, suggesting significant potential for widespread clinical adoption across diverse endoscopic environments.

Video 1.

Closure of a 38×35 mm gastric mucosal defect using the side-hole method. The side hole of the transparent hood is positioned at the 6 o'clock position to optimize direction control.
A video related to this article can be found online at https://doi.org/10.5946/ce.2025.183.
Fig. 1.
Side-hole method. A synthetic absorbable suture thread was affixed to the arm section of the EZ clip (A) and passed through the side hole of a transparent hood (B).
ce-2025-183f1.jpg
Fig. 2.
Closure of the gastric mucosal defect using a side-hole method. (A) Early gastric tumor, approximately 13×12 mm in size. (B–D) Mucosal defect after endoscopic submucosal dissection. (E) The first clip with the thread was fixed on the anal side of the edge of the mucosal defect. (F–G) The edges of the mucosal defect were sequentially clipped with the thread using EZ clips. (H) The remaining thread was cut using a scissor device. (I) Complete closure of the mucosal defect.
ce-2025-183f2.jpg
  • 1. Kobara H, Tada N, Fujihara S, et al. Clinical and technical outcomes of endoscopic closure of postendoscopic submucosal dissection defects: Literature review over one decade. Dig Endosc 2023;35:216–231.ArticlePubMedPDF
  • 2. Yahagi N, Nishizawa T, Akimoto T, et al. New endoscopic suturing method: string clip suturing method. Gastrointest Endosc 2016;84:1064–1065.ArticlePubMed
  • 3. Nomura T, Sugimoto S, Temma T, et al. Reopenable clip-over-the-line method for closing large mucosal defects following gastric endoscopic submucosal dissection: Prospective feasibility study. Dig Endosc 2023;35:505–511.ArticlePubMedPDF

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Mucosal defect closure using the side hole of a transparent hood
        Clin Endosc. 2026;59(3):470-471.   Published online August 18, 2025
        Close
      • XML DownloadXML Download
      Figure
      • 0
      • 1
      Mucosal defect closure using the side hole of a transparent hood
      Image Image
      Fig. 1. Side-hole method. A synthetic absorbable suture thread was affixed to the arm section of the EZ clip (A) and passed through the side hole of a transparent hood (B).
      Fig. 2. Closure of the gastric mucosal defect using a side-hole method. (A) Early gastric tumor, approximately 13×12 mm in size. (B–D) Mucosal defect after endoscopic submucosal dissection. (E) The first clip with the thread was fixed on the anal side of the edge of the mucosal defect. (F–G) The edges of the mucosal defect were sequentially clipped with the thread using EZ clips. (H) The remaining thread was cut using a scissor device. (I) Complete closure of the mucosal defect.
      Mucosal defect closure using the side hole of a transparent hood

      Clin Endosc : Clinical Endoscopy Twitter Facebook
      Close layer
      TOP