Image of Issue Rare complication of plastic endoscopic retrograde biliary drainage stent placement: bile duct perforation
Akinobu Koiwaiorcid, Morihisa Hirotaorcid, Yuki Miyashitaorcid, Nana Inomataorcid, Kennichi Satohorcid
Clinical Endoscopy 2026;59(5):853-854.
DOI: https://doi.org/10.5946/ce.2025.400
Published online: February 2, 2026

Division of Gastroenterology, Tohoku Medical and Pharmaceutical University, Sendai, Japan

Correspondence: Akinobu Koiwai Division of Gastroenterology, Tohoku Medical and Pharmaceutical University, 1-15-1, Fukumuro, Miyaginoku, Sendai City, Miyagi, 983-8536, Japan E-mail: a.koiwai@tohoku-mpu.ac.jp
• Received: October 23, 2025   • Revised: November 16, 2025   • Accepted: November 17, 2025

© 2026 Korean Society of Gastrointestinal Endoscopy

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 1,613 Views
  • 251 Download
prev next
A 63-year-old woman with diabetes mellitus and bronchial asthma presented with abdominal pain and a fever. Laboratory tests revealed elevated levels of inflammatory markers and hepatobiliary enzymes. Contrast-enhanced computed tomography (CT) revealed an impacted stone in the distal common bile duct (CBD) and multiple hepatic abscesses, consistent with acute cholangitis with secondary abscesses. Endoscopic retrograde cholangiopancreatography was performed. After endoscopic sphincterotomy, the stone was removed, and a 5-Fr double-pigtail plastic endoscopic retrograde biliary drainage (ERBD) stent was placed into the right intrahepatic bile duct (Fig. 1A). The infection improved, and the patient was discharged with the stent left in situ to prevent recurrent cholangitis before cholecystectomy.
Three months later, intraoperative laparoscopy revealed that the proximal end of the ERBD stent had penetrated the CBD wall and was protruding outside the bile duct (Fig. 1B). The tip was covered with serosa with no bile leakage. Postoperative CT showed no fistulae (Fig. 1C). Fluoroscopy revealed that the proximal end of the right hepatic duct, had migrated to the CBD (Fig. 2A). After stent removal, cholangiography revealed contrast pooling within the shallow wall depression, but no bile leakage (Fig. 2B). To prevent bile leakage, an endoscopic nasobiliary drainage tube was placed for one week. Follow-up imaging confirmed resolution (Fig. 2C, D).
Plastic ERBD stents are widely used,1 and complications can include stent occlusion, migration, and cholangitis.1,2 Migration occurs in 5% to 10% of cases.2,3 CBD wall perforation caused by a thin (5-Fr) plastic stent has not previously been reported. Possible mechanisms include chronic mechanical irritation of the bile duct wall by the stent tip, induced by respiratory and peristaltic motion. These forces may cause localized ischemia and erosion, resulting in delayed perforation.
This case highlights that even small-caliber plastic stents can lead to rare complications, warranting careful follow-up after placement.
Fig. 1.
(A) Endoscopic retrograde biliary drainage (ERBD) stent (5-Fr double-pigtail plastic stent) was placed into the right intrahepatic bile duct. (B) Intraoperative laparoscopic view revealing that proximal end of the ERBD stent (arrow) had migrated through the bile duct wall and partially protruding outside the duct. (C) Postoperative computed tomography showed the proximal end of the ERBD stent (arrow) protruding outside the bile duct wall. No fluid accumulation suggestive of bile leakage was identified.
ce-2025-400f1.jpg
Fig. 2.
(A) Fluoroscopy confirmed that the proximal end of the stent had protruded outside the bile duct (arrow). (B) Cholangiography after endoscopic retrograde biliary drainage stent removal showing slight contrast leakage (arrow) at the site of penetration, without evidence of active bile leakage. (C) To prevent potential bile leakage, an endoscopic nasobiliary drainage tube (6-Fr pigtail) was placed. (D) Follow-up cholangiography (one week later) showed no further contrast leakage.
ce-2025-400f2.jpg
  • 1. Dumonceau JM, Tringali A, Papanikolaou IS, et al. Endoscopic biliary stenting: indications, choice of stents, and results: European Society of Gastrointestinal Endoscopy (ESGE) clinical guideline-updated October 2017. Endoscopy 2018;50:910–930.ArticlePubMed
  • 2. Johanson JF, Schmalz MJ, Geenen JE. Incidence and risk factors for biliary and pancreatic stent migration. Gastrointest Endosc 1992;38:341–346.ArticlePubMed
  • 3. Katsinelos P, Kountouras J, Paroutoglou G, et al. Migration of plastic biliary stents and endoscopic retrieval: an experience of three referral centers. Surg Laparosc Endosc Percutan Tech 2009;19:217–221.ArticlePubMed

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Rare complication of plastic endoscopic retrograde biliary drainage stent placement: bile duct perforation
        Clin Endosc. 2026;59(5):853-854.   Published online February 2, 2026
        Close
      • XML DownloadXML Download
      Figure
      • 0
      • 1
      Related articles
      Rare complication of plastic endoscopic retrograde biliary drainage stent placement: bile duct perforation
      Image Image
      Fig. 1. (A) Endoscopic retrograde biliary drainage (ERBD) stent (5-Fr double-pigtail plastic stent) was placed into the right intrahepatic bile duct. (B) Intraoperative laparoscopic view revealing that proximal end of the ERBD stent (arrow) had migrated through the bile duct wall and partially protruding outside the duct. (C) Postoperative computed tomography showed the proximal end of the ERBD stent (arrow) protruding outside the bile duct wall. No fluid accumulation suggestive of bile leakage was identified.
      Fig. 2. (A) Fluoroscopy confirmed that the proximal end of the stent had protruded outside the bile duct (arrow). (B) Cholangiography after endoscopic retrograde biliary drainage stent removal showing slight contrast leakage (arrow) at the site of penetration, without evidence of active bile leakage. (C) To prevent potential bile leakage, an endoscopic nasobiliary drainage tube (6-Fr pigtail) was placed. (D) Follow-up cholangiography (one week later) showed no further contrast leakage.
      Rare complication of plastic endoscopic retrograde biliary drainage stent placement: bile duct perforation

      Clin Endosc : Clinical Endoscopy Twitter Facebook
      Close layer
      TOP