Department of Internal Medicine, Chungnam National University College of Medicine, Daejeon, Korea
© 2026 Korean Society of Gastrointestinal Endoscopy
This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Conflicts of Interest
The author has no potential conflicts of interest.
Funding
None.
Acknowledgments
The author gratefully acknowledge Dr. Ji Yong Ahn (University of Ulsan College of Medicine), Dr. Yunho Jung (Soonchunhyang University College of Medicine), and Dr. Joon Sung Kim (The Catholic University of Korea, College of Medicine) for providing representative clinical images used in Figure 2. The author also thank NexPowder for providing the device images used in Figure 3. Portions of the manuscript were assisted by an AI language model (ChatGPT, OpenAI) for language editing and readability. All scientific content, interpretation, and final editing were performed by the author.
Based on Gralnek et al. Endoscopy 2021;53:300–332.7
| Modality | Advantages | Limitations/drawbacks |
|---|---|---|
| Injection (epinephrine, sclerosant) | Simple, improves visualization, transient vasoconstriction | Only temporary effect, high rebleeding rate (>30%) if used alone, tissue injury with sclerosant |
| TTS Clip (through-the-scope clip) | Immediate mechanical closure, safe | Difficult in tangential or fibrotic lesions, poor adhesion, limited in large-caliber vessel bleeding |
| Thermal contact (heater/bipolar probe) | Seals exposed vessels, widely available | Risk of deep tissue injury/perforation, operator-dependent pressure, less effective in spurting bleeding |
| Argon plasma coagulation | Non-contact, covers wide area | Shallow coagulation, not effective for active spurting, possible gas embolism |
| Combination therapy | Improves hemostasis rate | Still 10%–20% rebleeding; multiple devices, time-consuming |
Based on Gralnek et al. Endoscopy 2021;53:300–332.