Original Article Impact of expert-curated video training data on computer-aided detection of sessile serrated lesions: a retrospective study in Korea
Jaehee Han1,2orcid, Sang-Il Oh3orcid, Piljoo Kim3orcid, Kyung-Nam Kim3orcid
Clinical Endoscopy 2026;59(5):821-832.
DOI: https://doi.org/10.5946/ce.2025.471
Published online: August 20, 2026

1Hanaro Medical Foundation, Seoul, Korea

2Hanaro Leaders Clinic, Seoul, Korea

3Waycen Inc., Seoul, Korea

Correspondence: Jaehee Han Hanaro Medical Foundation, Hanaro Leaders Clinic, 508, Eonju-ro, Gangnam-gu, Seoul 06152, Korea E-mail: crushpear@naver.com
• Received: December 22, 2025   • Revised: March 24, 2026   • Accepted: April 7, 2026

© 2026 Korean Society of Gastrointestinal Endoscopy

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 1,367 Views
  • 137 Download
  • 1 Web of Science
  • 1 Crossref
prev next
See letter "More frames or better labels?: training data and computer-aided detection of sessile serrated lesions" in Volume 59 on page 771.
  • Background/Aims
    Computer-aided detection (CADe) improves adenoma detection; however, its performance for sessile serrated lesion (SSL) detection remains inconsistent. We hypothesized that models trained on expert-curated, histopathologically-confirmed datasets would improve SSL detection compared to models trained on public datasets without verified labels.
  • Methods
    Two CADe models with identical Visual Geometry Group 16 architectures were trained using different datasets: Model A on public datasets (~54,000 frames) and model B on a histopathologically-confirmed private dataset (~120,000 frames) derived from examinations performed by endoscopists with adenoma detection rates of >35%. Validation was conducted using 31 independent colonoscopy videos obtained from another endoscopist. Diagnostic performance was evaluated using event- and frame-based analyses.
  • Results
    Model B demonstrated a significantly higher event-based sensitivity than model A (99.7% vs. 39.9%, p<0.001). The detection of SSLs was markedly improved with model B. Frame-based sensitivity and F1-score were also higher for model B. Although model B generated more false positives per video (2.55 vs. 0.16, p<0.001), these alerts were brief and unlikely to meaningfully interfere with the endoscopic workflow.
  • Conclusions
    CADe models trained on expert-curated, histopathologically-confirmed datasets showed improved detection of neoplastic colorectal lesions, including SSLs, compared to models trained on public datasets. These findings highlight the importance of clinically curated datasets for optimizing the CADe performance for subtle colorectal lesions.
Colorectal cancer (CRC) remains a leading cause of cancer-related mortality worldwide.1 Early detection and removal of precancerous lesions through high-quality colonoscopy are therefore essential for reducing CRC’s incidence and mortality.2 Accordingly, quality indicators such as the adenoma detection rate (ADR) have been widely adopted to assess colonoscopy performance.3-5 In recent years, deep learning-based computer-aided detection (CADe) systems have demonstrated consistent benefits in improving ADRs and have increasingly been incorporated into routine colonoscopic practice.6-9
Despite these advances, the detection of sessile serrated lesions (SSLs) remains challenging. SSLs are recognized precursors of interval CRC and are frequently missed during colonoscopy because of their subtle morphological characteristics, including a flat configuration, indistinct borders, and the presence of mucus caps.10,11 Earlier clinical studies and meta-analyses have suggested that while CADe systems consistently improved the detection of conventional adenomas, their benefit in serrated lesions was less consistent.12 More recent meta-analyses and reviews have reported increasing evidence that CADe-assisted colonoscopy may improve the detection of serrated lesions.13,14 Nevertheless, these studies primarily describe higher SSL detection rates during CADe-assisted procedures rather than directly evaluating the intrinsic ability of CADe systems to detect SSLs.
Importantly, real-world evidence suggests that the performance of CADe systems for SSL detection may vary depending on lesion characteristics and examiner expertise. One study reported that, although CADe systems improved the overall polyp detection accuracy, their impact on SSL detection remained influenced by lesion difficulty and user background.15 These findings suggest that the statistical improvements observed in pooled analyses may not fully translate into consistent performance across different clinical contexts.
From a technical perspective, CADe systems analyze visual information within the endoscopic field. Lesions that are incompletely exposed, located at the periphery of the visual field, or intermittently obscured by mucosal folds may limit consistent frame-level recognition. Tandem colonoscopy studies have shown that missed lesions are frequently associated with incomplete mucosal visualization, particularly for small or flat polyps.16 These characteristics may contribute to difficulty in detecting SSLs, which often present with subtle, indistinct borders.
In addition, SSLs have historically been reported less frequently during colonoscopy than conventional adenomas, potentially resulting in their underrepresentation in training datasets.10,17 Their subtle visual characteristics, including mucus caps and cloud-like surface patterns, may make them more difficult to recognize than protruding adenomas.10 Together, these clinical and technical considerations suggest that CADe system performance for SSL detection may depend not only on the algorithm architecture but also on the composition of the training dataset.
A common strategy for improving the deep learning performance is to increase the dataset size. However, its efficacy remains unclear. Although the model performance generally improves with larger datasets, prior studies have suggested the existence of a performance plateau, particularly when label uncertainty or heterogeneity is present.18,19 Furthermore, in medical imaging, privacy regulations and ethical constraints limit the acquisition of large-scale, high-quality annotated data.
Given these considerations, we hypothesized that the performance of CADe systems for SSL detection may be influenced not only by the dataset size, but also by data curation strategies.
The primary objective of this study was to evaluate whether an expert-curated, histopathologically-confirmed colonoscopy video dataset derived from high-performing endoscopists could improve CADe system detection performance, particularly for SSLs, compared to models trained on publicly available datasets, while keeping the algorithm architecture constant.
Study design and data sources
This retrospective study used endoscopic video data from a single high-volume center (Hanaro Medical Foundation). The training dataset for the proposed model (model B) was derived from a commercial CADe system (WAYMED Endo; Waycen Inc.) operating between November 2022 and September 2023.
During the initial deployment, the CADe system was installed and operated primarily for device testing and performance evaluation rather than for active model development. To ensure exposure to a wide range of lesions, we strategically selected two endoscopy rooms: one equipped with an Olympus CV-290 and the other with a CV-190 (Olympus Corp.). The two endoscopy rooms were managed by two dedicated endoscopists (endoscopists A and B), one assigned to each room, both of whom had maintained an ADR exceeding 35% over the preceding 6 months. This threshold was selected based on prior studies suggesting that ADR levels above 30%–35% are associated with a reduced risk of interval CRC.3,4 While the institutional average ADR during the study period was 31% (range, 19.8%–45.3%), these endoscopists consistently exceeded this level. Both endoscopists provided consent to use the CADe system. This configuration enabled monitoring across a broad spectrum of colorectal lesions and facilitated subsequent research activities, including refining detection algorithms.
For routine device performance feedback, full-length colonoscopy videos were automatically saved at the start of each examination. To protect patient privacy, the peripheral regions containing patient-identifiable information were cropped while preserving the entire endoscopic field. These videos were not originally collected for research purposes; they were stored locally on the device in an offline state, strictly prohibited from being exported, and were inaccessible to external networks.
The examination details were verified by cross-referencing video timestamps with images stored in the Picture Archiving and Communication System (PACS). Through this review process, 2,757 colonoscopy videos were identified, including 1,432 examinations performed using CV-190 and 1,325 examinations performed using CV-290.
Among the CV-190 examinations, 597 were normal screening colonoscopies without interventions, and 835 involved endoscopic resections or biopsies. Among the CV-290 examinations, 368 were normal screening examinations, and 957 involved resections or biopsies. The identified videos were screened for inclusion in the training dataset. Among the videos with adequate bowel preparation, 431 were selected for model training. These included 43 videos without detectable lesions (normal mucosa), 155 videos containing only hyperplastic polyps, and 233 videos containing neoplastic lesions, including adenomas and SSLs.
Subsequently, frames containing lesions were extracted from the selected videos and matched with histopathology reports. Pathological diagnoses were confirmed based on official histopathology reports issued by board-certified pathologists at Hi-Lab, Hanaro Medical Foundation, according to the 2019 World Health Organization classification criteria. This process generated a histopathologically-confirmed ground truth, ensuring that the dataset included clinically significant lesions, specifically adenomas and SSLs (Fig. 1). This study was conducted in accordance with the principles of the Declaration of Helsinki.
Deep learning algorithm
We utilized the core engine of WAYMED Endo, which uses a Visual Geometry Group (VGG)-16-based Convolutional Neural Network architecture20 optimized for real-time processing (>30 fps). The system identifies lesions using a circular region of interest to minimize visual distractions (Fig. 2).
The VGG16 architecture was selected as the backbone for two reasons. First, VGG16 is a widely established benchmark in medical image analysis, recognized for its robust capability to extract detailed textural and morphological features that are critical for identifying subtle lesions such as SSLs. Second, employing a standardized architecture allowed us to strictly isolate the training dataset as the primary variable influencing performance. By excluding complex state-of-the-art architectures, we aimed to demonstrate that the performance improvements were derived from data quality and clinical relevance rather than algorithmic superiority. We trained two identical models (model A and model B) using the same architecture, hyperparameters, and augmentation strategies, differing only in the training data sources.
Training datasets

1) Model A (public benchmark)

Trained on a total of 54,000 frames derived from public datasets (CVC-ClinicDB,21 Kvasir-SEG,22 and EndoCV23). This dataset comprised 19,632 original static images provided by the datasets and 34,368 frames extracted from 87 video sequences. Similar to model B, lesion frames from the videos were extracted from lesion appearance to disappearance. The ground truth for these images relied on visual consensus, and the ADR of the endoscopists was unknown.

2) Model B (proposed private)

Trained on approximately 120,000 frames extracted from 431 videos (255 using CV-190 and 176 using CV-290; Olympus Corp.) recorded by two expert endoscopists (endoscopists A and B) (ADR >35%). Although the training dataset size differed from that of model A, we retained the fully curated dataset to preserve the real-world training distribution. This approach was intended to reflect the real-world data accumulation encountered during commercial deployment.24 The dataset comprised approximately 47.2% of neoplastic lesions and 19.5% of hyperplastic polyps at the frame level, all confirmed by histopathology, whereas the remaining data consisted of normal mucosa. The detailed characteristics of the training datasets for both models are summarized in Table 1 and Supplementary Tables 1 and 2.
Validation dataset and evaluation
For the validation dataset, we selected 31 independent colonoscopy videos performed by a separate endoscopist (endoscopist C) who was not involved in the training phase. To prevent data leakage, videos were collected during a strictly separate period and stored on an isolated device that was never used during model training, validation, or hyperparameter tuning. Following institutional review board (IRB) approval, a retrospective review was conducted. The ground truth was established by cross-referencing endoscopic findings recorded in the PACS with corresponding pathology reports. To ensure consistency in the temporal annotations, specific intervals between lesion appearance and disappearance were defined by a single board-certified gastroenterologist.
Performance evaluation criteria
We evaluated the performance using both event- and frame-based analyses. The target lesions included neoplastic (adenomas and SSLs) and non-neoplastic (hyperplastic, inflammatory, and hamartomatous) polyps. Lymphoid polyps were excluded because of their lack of clinical relevance in screening settings.

1) Event-based analysis (clinical utility)

This served as the primary evaluation method using a validation dataset of 396 events consisting of 298 positive lesion events and 98 non-lesion events (negative controls). An event was defined as the entire interval from the appearance to the disappearance of a lesion. Detection was considered a True Positive (TP) if the model correctly localized (overlapped with the ground truth) the target lesion at least once during this interval. A False Negative (FN) was defined as a case where an actual lesion appeared on the screen, but the model failed to detect it throughout the interval. Conversely, a False Positive (FP) was defined as any instance in which the model localized normal mucosa or non-target lesions. To mimic clinical impacts, continuous FP frames were grouped and counted as single FP events. To ensure careful evaluation, we excluded intervals corresponding to the procedural phase, defined as frames where surgical instruments occupied approximately 50% or more of the screen diagonal, as well as the immediate post-procedure periods. Intervals with severe visual obstruction owing to water turbulence or blurring were also excluded.

2) Frame-based analysis (technical precision)

Performance was assessed on a frame-by-frame basis to evaluate detection stability. Detection was classified as a TP if the model correctly localized a target lesion within a frame containing one (visually overlapped with the lesion), whereas a FN was defined as an instance in which a lesion was present in the frame but the model failed to detect it. For frames without lesions, a True Negative (TN) was defined as an instance in which no lesion existed, and the model correctly did not output a detection. Conversely, an FP was defined as any instance in which the model was localized to the normal mucosa or non-target lesions. Consistent with the event-based criteria, frames identified as the procedural phase (surgical instruments occupying ≥50% of the screen diagonal) or those capturing the immediate post-procedure period were excluded. Frames with compromised visibility due to severe artifacts, such as bubbles, debris, or motion blurs, were also removed to ensure diagnostic accuracy.
To quantitatively assess the diagnostic performance, standard metrics were derived from the confusion matrix elements. However, the applicable metrics differed according to analysis type.
In the frame-based analysis, where TNs were definable, we utilized the full set of metrics: (1) Recall (sensitivity)=TP/(TP+FN); (2) Specificity=TN/(TN+FP); (3) Accuracy=(TP+TN)/(TP+TN+FP+FN); (4) Positive predictive value (PPV) (precision)=TP/(TP+FP); (5) Negative predictive value (NPV)=TN/(TN+FN); (6) F1-score=2×precision×recall/(precision+recall); (7) False negative rate (FNR)=FN/(TP+FN); (8) False positive rate (FPR)=FP/(FP+TN); (9) False discovery rate (FDR)=FP/(TP+FP); (10) FPs per video = total fps/total validation videos.
Conversely, in event-based analysis, defining discrete TN events was inherently ambiguous because of the difficulty in segmenting continuous non-lesion intervals into countable units; thus, metrics relying on TNs (specificity, accuracy, NPV, and FPR) were excluded. Instead, this analysis focused on sensitivity, precision, F1-score, and FNRs. Additionally, clinically relevant metrics were analyzed to assess the potential for alert fatigue: the FDR and number of FPs per video.
Finally, latency was defined as the time interval between the first frame in which a lesion became visible and the first frame in which the model generated the detection.
Statistical analyses
Statistical analyses were performed using Python ver. 3.9.7. For event-based analysis, the statistical significance of paired binary comparisons, including sensitivity and FNR, was assessed using McNemar’s test. For metrics involving ratios with varying denominators or non-normal distributions (PPV, F1-score, and FDR), we utilized bootstrap resampling with 2,000 iterations to estimate 95% confidence intervals (CIs) and p-values. The number of FPs per video was compared using the Wilcoxon signed-rank test to account for the non-normal distribution of false alarm counts across the validation videos.
For frame-based analysis, performance metrics were calculated by pooling TPs, FPs, TNs, and FNs across all validation videos. To estimate the 95% CIs, we employed bootstrap resampling at the case level with 2,000 iterations. Statistical comparisons between models A and B were performed using the Wilcoxon signed-rank test on case-level performance metrics to account for the paired nature of the data and the variability in frame counts. The detection latency and tracking duration were compared using the Mann-Whitney U-test and Student’s t-test, respectively. A p-value of < 0.05 was considered statistically significant.
Ethical statements
This study was approved by the IRB of Hanaro Medical Foundation as an exempt study (No. HNR2023-05). The requirement for informed consent was waived due to the retrospective nature of the study.
Training dataset characteristics
The characteristics of the training dataset used for model B are summarized in Table 1 and Supplementary Tables 1 and 2. Approximately 120,000 frames were extracted from 431 colonoscopy videos, including 56,605 frames of neoplastic lesions (adenomas and SSLs), 23,389 frames of hyperplastic polyps, and 40,006 frames of normal mucosa.
Baseline characteristics of the validation set
Thirty-one patients were included in the validation dataset (16 males [51.6%] and 15 females [48.4%]). The mean age was 50.8 years (range, 32–68 years). The validation dataset contained 460,201 video frames. We identified 122 unique lesions that corresponded to 298 distinct lesion appearance events in the event-based analysis (Table 2). Adenomas were the most common finding (54.4%, 162/298), followed by SSLs (13.4%, 40/298). Hyperplastic polyps accounted for 31.2% (93/298) of the cases, and one juvenile polyp was found (1.0%, 3/298).
Diagnostic performance of model A and model B
The diagnostic performance of models A and B is summarized in Table 3. Model B showed significantly higher event-based sensitivity than model A (99.7% [95% CI, 99.0%–100.0%] vs. 39.9% [95% CI, 34.6%–45.5%]; p<0.001). The FNR was 0.3% for model B and 60.1% for model A. By histopathological type, model A detected 48.1% of adenoma events and 12.5% of SSL events, whereas model B detected 99.4% and 100.0%, respectively (Fig. 3). Model B also showed higher sensitivity for total neoplastic events than model A (99.5% vs. 41.1%). The F1-score was higher for model B than for model A (0.881 vs. 0.564, p<0.001). The mean number of FPs per video was higher for model B than for model A (2.55±2.26 vs. 0.16±0.45, p<0.001). The FDR was 21.0% for model B and 4.0% for model A.
Frame-based detection stability
For frame-based analysis, 153,370 frames were excluded because of procedural phases or poor visualization. The final analysis identified 365 distinct sequences (Table 4). Consistent with the event-based analysis, model B showed a significantly higher frame-level sensitivity (52.8%) than model A (16.8%) (p<0.001). The F1-score was also higher in model B (0.678 vs. 0.287, p<0.001).
Table 5 lists the detection latencies and tracking durations. The median detection latency was shorter in model B (0.33 seconds) than in model A (0.62 seconds) (p<0.001). Specifically, the median latency of model B was 0.30 seconds for adenomas and 0.25 seconds for SSLs. The average duration of lesion visibility was approximately 3.0 seconds (88.4 frames). Among lesion sequences in which the corresponding model generated at least one correct ROI, model B showed a longer mean tracking duration and a higher mean sequence-level tracking ratio than model A (51.6 frames and 53.4% vs. 41.1 frames and 35.3%, respectively). Tracking ratios were calculated for each lesion sequence and then averaged. In terms of the tracking ratio distribution, model A’s detection was predominantly concentrated in the 0%–10% tracking range (n=264). Model B showed a broader distribution across the higher tracking-ratio intervals (Fig. 4). The average duration of the FP alerts was 10.9 frames (0.36 seconds) for model B and 2.6 frames (0.09 seconds) for model A.
Sub-analysis of sessile serrated lesions
Table 6 summarizes the clinicopathological characteristics of the 14 SSLs. Most of the SSLs (92.9%, 13/14) were located in the proximal colon.
The present study demonstrated that a CADe system trained on an expert-curated, histopathologically-confirmed colonoscopy video dataset showed substantially improved detection performance for colorectal lesions, particularly SSLs, compared to a model trained on publicly available datasets using the same neural network architecture. Notably, model B achieved near-complete detection of both adenomas and SSLs in the validation dataset while also demonstrating shorter detection latency and more stable lesion tracking across frames. These findings suggest that the characteristics of the training dataset may play a critical role in determining the CADe system’s performance, particularly for subtle lesions such as SSLs. Previous studies have consistently shown that CADe systems can improve adenoma detection during colonoscopy. However, their performance for serrated lesions remains variable.12-14
A key issue raised in this study relates to the relative importance of dataset quantity versus quality in deep-learning-based medical imaging systems. In this study, model B was trained on a larger dataset than model A. Therefore, part of the performance improvement may be attributable to the increased number of training frames. Therefore, the present study should be interpreted as a comparison between a public benchmark dataset and a clinically curated real-world dataset, rather than a strictly size-matched experimental comparison. In addition, the primary distinction between the two datasets lies not only in their size but also in their clinical curation. The training data for model B consisted of full-length colonoscopy videos recorded by experienced endoscopists with high ADRs and included histopathologically-confirmed lesions, whereas the public datasets used for model A largely relied on visually annotated images with heterogeneous clinical backgrounds. Public benchmark datasets have facilitated the development and benchmarking of artificial intelligence systems in endoscopy; however, they may not fully represent the variability and complexity encountered in real-world clinical practice.23,24 Such differences in annotation reliability and clinical context may influence the performance of deep learning models in medical image analysis.18,19
Interestingly, the training dataset demonstrated a notable discrepancy between the lesion-level prevalence and frame-level representation. Although hyperplastic polyps were more frequent at the lesion level, a substantially larger number of frames was extracted from neoplastic lesions, including adenomas and SSLs. This pattern likely reflects routine clinical behavior during colonoscopy. When a potentially neoplastic lesion is encountered, endoscopists typically spend additional time carefully examining the lesion margins, washing to remove mucus, and evaluating surface patterns prior to resection. In contrast, diminutive hyperplastic polyps often require only brief inspection. Consequently, neoplastic lesions were captured across a large number of frames from diverse visual perspectives. From a data-centric artificial intelligence perspective, this phenomenon can be interpreted as a form of natural data enrichment in which clinically important lesions are inherently represented by a larger and more diverse set of visual examples. Additionally, lesions in the expert-curated dataset were captured across multiple viewing angles and procedural contexts, including washing, magnified inspection, and pre-resection observation, further increasing the visual diversity within the training data. This enriched representation may have contributed to the improved detection of SSLs in this study.10,11,17
Another important finding was the shorter detection latency observed with model B. Because both models used the same neural network architecture and inference pipeline, the difference in latency was unlikely to reflect differences in computational speed. Instead, the reduced latency likely reflected earlier visual recognition of lesions within the endoscopic field. In practical terms, the model trained on expert-curated data may have learned more discriminative visual features associated with subtle mucosal abnormalities, enabling it to generate alerts closer to the moment when lesions first became visible during colonoscopy. Early recognition of subtle lesions may be particularly relevant for SSLs, which often present faint borders and indistinct mucosal patterns that can be challenging to detect in routine practice.10,11,15
Model B generated a higher number of FP alerts per video than model A. However, the average duration of these alerts was short (approximately 0.36 seconds), indicating that most detections were transient and, therefore, unlikely to meaningfully interfere with the endoscopic workflow or the endoscopist’s visual attention during routine colonoscopy. In clinical practice, such brief alerts may indicate the sensitivity of a model to subtle mucosal patterns that partially resemble polypoid structures. In the context of CADe systems, a modest increase in transient FPs may represent an acceptable trade-off for substantially improved sensitivity in detecting clinically significant lesions, particularly SSLs, which are easily overlooked during colonoscopy.10,11
This study had several limitations. First, the training dataset used for model B was larger than the public dataset used for model A. Therefore, the effects of dataset size and curation could not be completely separated. Second, the study was conducted using data from a single center and a limited number of endoscopists, which may limit the generalizability of the findings. Third, although pathologically confirmed lesions were used to establish the ground truth, frame-level annotations were derived retrospectively and may have been influenced by subjective interpretation. Future multicenter studies with size-matched training datasets and prospective validation are necessary to further clarify the relative contributions of the dataset size and expert-driven data curation to CADe system development.23-25
In conclusion, our findings suggest that expert-curated colonoscopy video datasets with histopathologically-confirmed lesions may contribute to improved CADe detection performance, particularly for challenging lesions such as SSLs. These results highlight the importance of clinically curated training data in the development of reliable artificial intelligence-assisted colonoscopy systems. Future research should further investigate the relative contributions of the dataset size, data curation, and annotation quality in optimizing the CADe system’s performance.
Supplementary Table 1. Frame distribution of the model B training dataset.
ce-2025-471-Supplementary-Table-1.pdf
Supplementary Table 2. Clinicopathologic characteristics of lesions included in the training dataset.
ce-2025-471-Supplementary-Table-2.pdf
Supplementary materials related to this article can be found online at https://doi.org/10.5946/ce.2025.471.
Fig. 1.
Flowchart of data curation and study design. The routine colonoscopy videos were anonymized and stored for monitoring. After institutional review board approval, videos were retrospectively reviewed and lesions were strictly matched with histopathology reports to establish the ground truth. Two identical Visual Geometry Group 16-based models were trained: Model A used public datasets and model B used the constructed histopathologically-confirmed private dataset. Both the models were evaluated using an independent validation set.
ce-2025-471f1.jpg
Fig. 2.
Representative frames from validation videos analyzed by model A and model B. Representative detection outcomes from validation videos analyzed using models A (left column) and B (right column). (A) A tubular adenoma successfully detected by both models. (B) A subtle sessile serrated lesion, typically difficult to detect, identified only by Model B. (C) A large polyp missed by Model A but correctly detected by Model B. (D) A false positive detection of normal vascular patterns by Model B, whereas Model A correctly ignored the artifact.
ce-2025-471f2.jpg
Fig. 3.
Comparison of event-based detection sensitivity between model A and model B, stratified by histopathological type. Sensitivity was calculated at the lesion appearance event level, consistent with the event-based analysis presented in Table 3. Repeated appearances of the same lesion were counted as separate events. Model B showed higher sensitivity than model A across all histopathological categories.
ce-2025-471f3.jpg
Fig. 4.
Distribution of lesion tracking ratios. The histogram illustrates the stability of the lesion tracking by comparing the detection ratio (percentage of frames in which the lesion was correctly detected relative to its total appearance duration) for the 365 valid lesion events. Model A (gray bars) showed a left-skewed distribution, indicating that it tracked the majority of lesions for less than 10% of their duration of appearance. In contrast, model B (blue bars) demonstrated a more balanced distribution, with a significant number of lesions tracked for over 50% of their duration, reflecting higher tracking stability and persistence. This suggests that model B maintained lesion recognition for longer portions of the lesion appearance interval, potentially increasing the likelihood of detection during real-time colonoscopy.
ce-2025-471f4.jpg
ce-2025-471f5.jpg
Table 1.
Comparison of training dataset characteristics between model A (public) and model B (proposed)
Characteristic Model A (public benchmark) Model B (proposed private)
Source type Public Databases (CVC, Kvasir, EndoCV) Single High-Volume Center (Korea)
Total frames ~54,000 ~120,000
Ground truth Visual consensus Pathology-confirmed
Target lesions Unspecified ‘polyp’ Neoplastic (47.2%), hyperplastic (19.5%)
Endoscopist skill Unknown High performers (ADR >35%)

All proportions are presented at the frame level after frame extraction from colonoscopy videos.

CVC, Computer Vision Center; ADR, adenoma detection rate.

Table 2.
Baseline demographics and lesion characteristics of the validation set
Characteristic Value (n=31)
Patient age (yr) 50.8 (32–68)
Sex (male/female) 16 (51.6)/15 (48.4)
Total frames 460,201 (153,370 excluded)
Total lesions (n, events) 122 (298)
 Adenoma (n, events) 62 (162) (54.4)
 Sessile serrated lesion (n, events) 14 (40) (13.4)
 Hyperplastic polyp (n, events) 45 (93) (31.2)
 Juvenile polyp (n, events) 1 (3) (1.0)

Values are presented as mean (range) or number (%).

Table 3.
Comparison of event-based performance metrics between model A and model B
Metric Model A (95% CI) Model B (95% CI) p-valuea)
Recall (sensitivity) (%) 39.9 (34.6–45.5) 99.7 (99.0–100.0) <0.001
PPV (precision) (%) 96.0 (92.3–99.2) 79.0 (74.7–82.9) <0.001
F1-score 0.564 (0.506–0.618) 0.881 (0.854–0.905) <0.001
FNR 60.1 (54.5–65.4) 0.3 (0.0–1.0) <0.001
FDR (%) 4.0 (0.8–7.7) 21.0 (17.1–25.3) <0.001
False positives/video 0.16±0.45 2.55±2.26 <0.001

Values are presented as percentages (95% CIs) or means±standard deviations.

CI, confidence interval; PPV, positive predictive value; FNR, false negative rate; FDR, false discovery rate.

a)p-values were calculated using McNemar’s test for sensitivity and FNR; bootstrap resampling for PPV and F1-score, FDR; and the Wilcoxon signed-rank test for false positives per video.

Table 4.
Comparison of frame-based performance metrics between model A and model B (n=365 sequences)
Metric Model A (95% CI) Model B (95% CI) p-valuea)
Recall (sensitivity) (%) 16.8 (11.7–22.6) 52.8 (46.6–58.5) <0.001
PPV (precision) (%) 97.8 (94.3–99.9) 94.7 (90.4–97.8) <0.001
Specificity 1.000 (0.999–1.000) 0.996 (0.994–0.998) <0.001
Accuracy 0.911 (0.891–0.929) 0.946 (0.935–0.957) <0.001
F1-Score 0.287 (0.210–0.368) 0.678 (0.620–0.728) <0.001
False negative rate (%) 83.2 (77.4–88.3) 47.2 (41.5–53.4) <0.001
False positive rate (%) 0.0 (0.0–0.1) 0.4 (0.2–0.6) <0.001
False discovery rate (%) 2.2 (0.1–5.7) 5.3 (2.2–9.6) <0.001
False positives (frames)/video 7.6 (0.1–18.9) 60.2 (12.7–134.2) <0.001

Values are presented as percentages (95% CIs) or mean scores.

CI, confidence interval; PPV, positive predictive value.

a)p-values were calculated using the Wilcoxon signed-rank test for case-level metrics. 95% CIs were estimated using bootstrap case resampling.

Table 5.
Comparative analysis of latency and tracking duration (model A vs. model B)
Model A Model B p-valuea)
Detection latency (median, s)
 Overall 0.62 0.33 <0.001
 Adenoma 0.58 0.30 <0.001
 SSL - (high failure rate)b) 0.25 N/A
Tracking duration (mean, frames)
 True positives (correct detection) 41.1 51.6 <0.01
 False positives (false alarm) 2.6 10.9 (approx. 0.36 s) <0.001

Latency, time from lesion appearance to first detection; tracking duration, average number of frames with a correct ROI during the lesion-visible interval, calculated among detected lesion sequences; tracking ratio, percentage of lesion-visible frames with a correct ROI, calculated for each lesion sequence and then averaged; ROI, region of interest; SSL, sessile serrated lesion; s, seconds; N/A, not applicable.

a)p-values were calculated using the Mann-Whitney U-test for latency and t-test for duration.

b)Insufficient data due to low detection rate.

Table 6.
Clinicopathologic characteristics of sessile serrated lesions
Characteristics Value (n=14)
Location
 Proximal colon (right-sided)a) 13 (92.9)
  Ascending colon 10 (71.4)
  Hepatic flexure 2 (14.3)
  Transverse colon 1 (7.1)
 Distal colon (left-sided)b) 1 (7.1)
  Splenic flexure 1 (7.1)
Size
 Diameter (mm) 5.8±2.4
 <5 (diminutive) 6 (42.9)
 5–9 (small) 7 (50.0)
 ≥10 (large) 1 (7.1)
Morphology (Paris classification)
 Type 0–IIa (flat elevation) 10 (71.4)
 Type 0–IIb (flat) 4 (28.6)

Values are presented as number (%) or mean±standard deviation.

a)The proximal colon includes the cecum, ascending colon, hepatic flexure, and transverse colon.

b)Distal colon includes the splenic flexure, descending colon, sigmoid colon, and rectum.

  • 1. Sung H, Ferlay J, Siegel RL, et al. Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 Countries. CA Cancer J Clin 2021;71:209–249.ArticlePubMedPDF
  • 2. Zauber AG, Winawer SJ, O'Brien MJ, et al. Colonoscopic polypectomy and long-term prevention of colorectal-cancer deaths. N Engl J Med 2012;366:687–696.ArticlePubMedPMC
  • 3. Kaminski MF, Regula J, Kraszewska E, et al. Quality indicators for colonoscopy and the risk of interval cancer. N Engl J Med 2010;362:1795–1803.ArticlePubMed
  • 4. Rex DK, Schoenfeld PS, Cohen J, et al. Quality indicators for colonoscopy. Gastrointest Endosc 2015;81:31–53.ArticlePubMed
  • 5. Park SB, Cha JM. Quality indicators in colonoscopy: the chasm between ideal and reality. Clin Endosc 2022;55:332–338.ArticlePubMedPMCPDF
  • 6. Repici A, Badalamenti M, Maselli R, et al. Efficacy of real-time computer-aided detection of colorectal neoplasia in a randomized trial. Gastroenterology 2020;159:512–520.ArticlePubMed
  • 7. Mori Y, Kudo SE, Misawa M, et al. Real-time use of artificial intelligence in identification of diminutive polyps during colonoscopy: a prospective study. Ann Intern Med 2018;169:357–366.ArticlePubMedPDF
  • 8. Maas MHJ, Neumann H, Shirin H, et al. A computer-aided polyp detection system in screening and surveillance colonoscopy: an international, multicentre, randomised, tandem trial. Lancet Digit Health 2024;6:e157–e165.ArticlePubMed
  • 9. Urban G, Tripathi P, Alkayali T, et al. Deep learning localizes and identifies polyps in real time with 96% accuracy in screening colonoscopy. Gastroenterology 2018;155:1069–1078.ArticlePubMedPMC
  • 10. Rex DK, Ahnen DJ, Baron JA, et al. Serrated lesions of the colorectum: review and recommendations from an expert panel. Am J Gastroenterol 2012;107:1315–1329.ArticlePubMedPMCPDF
  • 11. van Toledo DE, IJspeert JE, Bossuyt PM, et al. Serrated polyp detection and risk of interval post-colonoscopy colorectal cancer: a population-based study. Lancet Gastroenterol Hepatol 2022;7:747–754.ArticlePubMed
  • 12. Hassan C, Spadaccini M, Iannone A, et al. Performance of artificial intelligence in colonoscopy for adenoma and polyp detection: a systematic review and meta-analysis. Gastrointest Endosc 2021;93:77–85.ArticlePubMed
  • 13. Spadaccini M, Menini M, Massimi D, et al. AI and polyp detection during colonoscopy. Cancers (Basel) 2025;17:797.ArticlePubMedPMC
  • 14. Shiha MG, Oka P, Raju SA, et al. Artificial intelligence-assisted colonoscopy for adenoma and polyp detection: an updated systematic review and meta-analysis. IGIE 2023;2:333–343.ArticlePubMedPMC
  • 15. Lee J, Cho WS, Kim BS, et al. Impact of user's background knowledge and polyp characteristics in colonoscopy with computer-aided detection. Gut Liver 2024;18:857–866.ArticlePubMedPMC
  • 16. Rex DK, Cutler CS, Lemmel GT, et al. Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies. Gastroenterology 1997;112:24–28.ArticlePubMed
  • 17. Tan CK, Suzuki S, Ang TL, et al. Sessile serrated lesion prevalence and factors associated with their detection: a post-hoc analysis of a multinational randomized controlled trial from Asia. Endoscopy 2024;56:684–693.ArticlePubMed
  • 18. Karimi D, Dou H, Warfield SK, et al. Deep learning with noisy labels: exploring techniques and remedies in medical image analysis. Med Image Anal 2020;65:101759.ArticlePubMedPMC
  • 19. Gong EJ, Bang CS, Lee JJ, et al. Impact of the volume and distribution of training datasets in the development of deep-learning models for the diagnosis of colorectal polyps in endoscopy images. J Pers Med 2022;12:1361.ArticlePubMedPMC
  • 20. Simonyan K, Zisserman A. Very deep convolutional networks for large-scale image recognition [Internet]. Oxford University Research Archive; 2015 [cited 2025 Dec 22]. Available from: https://ora.ox.ac.uk/objects/uuid:60713f18-a6d1-4d97-8f45-b60ad8aebbce
  • 21. Bernal J, Sánchez FJ, Fernández-Esparrach G, et al. WM-DOVA maps for accurate polyp highlighting in colonoscopy: Validation vs. saliency maps from physicians. Comput Med Imaging Graph 2015;43:99–111.ArticlePubMed
  • 22. Jha D, Smedsrud PH, Riegler MA, et al. Kvasir-SEG: a segmented polyp dataset. Lect Comput Sci 2020;451–462.Article
  • 23. Ali S, Jha D, Ghatwary N, et al. A multi-centre polyp detection and segmentation dataset for generalisability assessment. Sci Data 2023;10:75.ArticlePubMedPMCPDF
  • 24. Biffi C, Antonelli G, Bernhofer S, et al. REAL-Colon: a dataset for developing real-world AI applications in colonoscopy. Sci Data 2024;11:539.ArticlePubMedPMCPDF
  • 25. Misawa M, Kudo SE, Mori Y, et al. Current status and future perspective on artificial intelligence for lower endoscopy. Dig Endosc 2021;33:273–284.ArticlePubMedPDF

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  
    • More frames or better labels?: training data and computer-aided detection of sessile serrated lesions
      Min-Jae Kim
      Clinical Endoscopy.2026; 59(5): 771.     CrossRef

    • Cite
      CITE
      export Copy Download
      Close
      Download Citation
      Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

      Format:
      • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
      • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
      Include:
      • Citation for the content below
      Impact of expert-curated video training data on computer-aided detection of sessile serrated lesions: a retrospective study in Korea
      Clin Endosc. 2026;59(5):821-832.   Published online August 20, 2026
      Close
    • XML DownloadXML Download
    Figure
    • 0
    • 1
    • 2
    • 3
    • 4
    Related articles
    Impact of expert-curated video training data on computer-aided detection of sessile serrated lesions: a retrospective study in Korea
    Image Image Image Image Image
    Fig. 1. Flowchart of data curation and study design. The routine colonoscopy videos were anonymized and stored for monitoring. After institutional review board approval, videos were retrospectively reviewed and lesions were strictly matched with histopathology reports to establish the ground truth. Two identical Visual Geometry Group 16-based models were trained: Model A used public datasets and model B used the constructed histopathologically-confirmed private dataset. Both the models were evaluated using an independent validation set.
    Fig. 2. Representative frames from validation videos analyzed by model A and model B. Representative detection outcomes from validation videos analyzed using models A (left column) and B (right column). (A) A tubular adenoma successfully detected by both models. (B) A subtle sessile serrated lesion, typically difficult to detect, identified only by Model B. (C) A large polyp missed by Model A but correctly detected by Model B. (D) A false positive detection of normal vascular patterns by Model B, whereas Model A correctly ignored the artifact.
    Fig. 3. Comparison of event-based detection sensitivity between model A and model B, stratified by histopathological type. Sensitivity was calculated at the lesion appearance event level, consistent with the event-based analysis presented in Table 3. Repeated appearances of the same lesion were counted as separate events. Model B showed higher sensitivity than model A across all histopathological categories.
    Fig. 4. Distribution of lesion tracking ratios. The histogram illustrates the stability of the lesion tracking by comparing the detection ratio (percentage of frames in which the lesion was correctly detected relative to its total appearance duration) for the 365 valid lesion events. Model A (gray bars) showed a left-skewed distribution, indicating that it tracked the majority of lesions for less than 10% of their duration of appearance. In contrast, model B (blue bars) demonstrated a more balanced distribution, with a significant number of lesions tracked for over 50% of their duration, reflecting higher tracking stability and persistence. This suggests that model B maintained lesion recognition for longer portions of the lesion appearance interval, potentially increasing the likelihood of detection during real-time colonoscopy.
    Graphical abstract
    Impact of expert-curated video training data on computer-aided detection of sessile serrated lesions: a retrospective study in Korea
    Characteristic Model A (public benchmark) Model B (proposed private)
    Source type Public Databases (CVC, Kvasir, EndoCV) Single High-Volume Center (Korea)
    Total frames ~54,000 ~120,000
    Ground truth Visual consensus Pathology-confirmed
    Target lesions Unspecified ‘polyp’ Neoplastic (47.2%), hyperplastic (19.5%)
    Endoscopist skill Unknown High performers (ADR >35%)
    Characteristic Value (n=31)
    Patient age (yr) 50.8 (32–68)
    Sex (male/female) 16 (51.6)/15 (48.4)
    Total frames 460,201 (153,370 excluded)
    Total lesions (n, events) 122 (298)
     Adenoma (n, events) 62 (162) (54.4)
     Sessile serrated lesion (n, events) 14 (40) (13.4)
     Hyperplastic polyp (n, events) 45 (93) (31.2)
     Juvenile polyp (n, events) 1 (3) (1.0)
    Metric Model A (95% CI) Model B (95% CI) p-valuea)
    Recall (sensitivity) (%) 39.9 (34.6–45.5) 99.7 (99.0–100.0) <0.001
    PPV (precision) (%) 96.0 (92.3–99.2) 79.0 (74.7–82.9) <0.001
    F1-score 0.564 (0.506–0.618) 0.881 (0.854–0.905) <0.001
    FNR 60.1 (54.5–65.4) 0.3 (0.0–1.0) <0.001
    FDR (%) 4.0 (0.8–7.7) 21.0 (17.1–25.3) <0.001
    False positives/video 0.16±0.45 2.55±2.26 <0.001
    Metric Model A (95% CI) Model B (95% CI) p-valuea)
    Recall (sensitivity) (%) 16.8 (11.7–22.6) 52.8 (46.6–58.5) <0.001
    PPV (precision) (%) 97.8 (94.3–99.9) 94.7 (90.4–97.8) <0.001
    Specificity 1.000 (0.999–1.000) 0.996 (0.994–0.998) <0.001
    Accuracy 0.911 (0.891–0.929) 0.946 (0.935–0.957) <0.001
    F1-Score 0.287 (0.210–0.368) 0.678 (0.620–0.728) <0.001
    False negative rate (%) 83.2 (77.4–88.3) 47.2 (41.5–53.4) <0.001
    False positive rate (%) 0.0 (0.0–0.1) 0.4 (0.2–0.6) <0.001
    False discovery rate (%) 2.2 (0.1–5.7) 5.3 (2.2–9.6) <0.001
    False positives (frames)/video 7.6 (0.1–18.9) 60.2 (12.7–134.2) <0.001
    Model A Model B p-valuea)
    Detection latency (median, s)
     Overall 0.62 0.33 <0.001
     Adenoma 0.58 0.30 <0.001
     SSL - (high failure rate)b) 0.25 N/A
    Tracking duration (mean, frames)
     True positives (correct detection) 41.1 51.6 <0.01
     False positives (false alarm) 2.6 10.9 (approx. 0.36 s) <0.001
    Characteristics Value (n=14)
    Location
     Proximal colon (right-sided)a) 13 (92.9)
      Ascending colon 10 (71.4)
      Hepatic flexure 2 (14.3)
      Transverse colon 1 (7.1)
     Distal colon (left-sided)b) 1 (7.1)
      Splenic flexure 1 (7.1)
    Size
     Diameter (mm) 5.8±2.4
     <5 (diminutive) 6 (42.9)
     5–9 (small) 7 (50.0)
     ≥10 (large) 1 (7.1)
    Morphology (Paris classification)
     Type 0–IIa (flat elevation) 10 (71.4)
     Type 0–IIb (flat) 4 (28.6)
    Table 1. Comparison of training dataset characteristics between model A (public) and model B (proposed)

    All proportions are presented at the frame level after frame extraction from colonoscopy videos.

    CVC, Computer Vision Center; ADR, adenoma detection rate.

    Table 2. Baseline demographics and lesion characteristics of the validation set

    Values are presented as mean (range) or number (%).

    Table 3. Comparison of event-based performance metrics between model A and model B

    Values are presented as percentages (95% CIs) or means±standard deviations.

    CI, confidence interval; PPV, positive predictive value; FNR, false negative rate; FDR, false discovery rate.

    p-values were calculated using McNemar’s test for sensitivity and FNR; bootstrap resampling for PPV and F1-score, FDR; and the Wilcoxon signed-rank test for false positives per video.

    Table 4. Comparison of frame-based performance metrics between model A and model B (n=365 sequences)

    Values are presented as percentages (95% CIs) or mean scores.

    CI, confidence interval; PPV, positive predictive value.

    p-values were calculated using the Wilcoxon signed-rank test for case-level metrics. 95% CIs were estimated using bootstrap case resampling.

    Table 5. Comparative analysis of latency and tracking duration (model A vs. model B)

    Latency, time from lesion appearance to first detection; tracking duration, average number of frames with a correct ROI during the lesion-visible interval, calculated among detected lesion sequences; tracking ratio, percentage of lesion-visible frames with a correct ROI, calculated for each lesion sequence and then averaged; ROI, region of interest; SSL, sessile serrated lesion; s, seconds; N/A, not applicable.

    p-values were calculated using the Mann-Whitney U-test for latency and t-test for duration.

    Insufficient data due to low detection rate.

    Table 6. Clinicopathologic characteristics of sessile serrated lesions

    Values are presented as number (%) or mean±standard deviation.

    The proximal colon includes the cecum, ascending colon, hepatic flexure, and transverse colon.

    Distal colon includes the splenic flexure, descending colon, sigmoid colon, and rectum.