Skip Navigation
Skip to contents

Clin Endosc : Clinical Endoscopy

OPEN ACCESS

Articles

Page Path
HOME > Clin Endosc > Ahead-of print articles > Article
Image of Issue Endoscopic ultrasound-guided lumen-apposing metal stent placement for intra-abdominal abscess management following gastric peroral endoscopic myotomy
Lexis Khetsavanh1orcid, Vaibhav Wadhwa2orcid, Wasseem Skef2orcid

DOI: https://doi.org/10.5946/ce.2026.130
Published online: August 25, 2026

1McGovern Medical School at UTHealth, Houston, TX, USA

2Center for Interventional Gastroenterology at UTHealth (iGUT), Department of Medicine, Division of Endoluminal Surgery and Interventional Gastroenterology, McGovern Medical School at UTHealth, Houston, TX, USA

Correspondence: Lexis Khetsavanh Center for Interventional Gastroenterology at UTHealth (iGUT), Department of Medicine, Division of Endoluminal Surgery and Interventional Gastroenterology, McGovern Medical School at UTHealth, 6431 Fannin St, MSB G300, Houston, TX 77030, USA E-mail: Lexis.P.Khetsavanh@uth.tmc.edu
• Received: March 23, 2026   • Revised: April 5, 2026   • Accepted: April 6, 2026

© 2026 Korean Society of Gastrointestinal Endoscopy

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 689 Views
  • 91 Download
A 62-year-old female with a medical history including orthotopic liver transplant requiring immunosuppression and medically refractory gastroparesis underwent gastric peroral endoscopic myotomy (GPOEM) using the lesser curvature (LC) approach. Mucosal closure was performed using endoclips. An upper gastrointestinal series confirmed no leaking prior to discharge. The patient also completed three days of prophylactic antibiotics. One week later, the patient presented with fever, nausea, vomiting, and abdominal pain. Computed tomography revealed a 13×8 cm abscess along the greater curvature of the stomach (Fig. 1). Endoscopy revealed clip dehiscence at the mucosotomy site (Fig. 2). The clips were removed and secure closure was achieved using endoscopic suturing (Fig. 3). The abscess was drained using a transgastric lumen-apposing metal stent (LAMS) under endosonographic (EUS) guidance (Fig. 4). Imaging after 3.5 weeks confirmed resolution of collection and the LAMS was removed.
Recent data suggest that the LC approach may be associated with fewer and milder adverse events.1 Endoclips and endoscopic suturing are comparable options for closure in GPOEM.2 Intra-abdominal abscess is a very rare complication of GPOEM. When encountered, such abscesses are typically drained via percutaneous or surgical methods. Although LAMS was initially approved for management of pancreatic fluid collections, it has since become widely adopted for a variety of off-label indications.3 This case highlights the successful use of EUS-guided LAMS, specifically to manage the GPOEM complication of an intrabdominal abscess in the stomach.
Fig. 1.
Computed tomography demonstrated a 13×8 cm abscess along the greater curvature of the stomach.
ce-2026-130f1.jpg
Fig. 2.
Endoscopy revealed clip dehiscence at the mucosotomy site. Arrows demonstrate the area of clip dehiscence.
ce-2026-130f2.jpg
Fig. 3.
Clips were removed and secure closure was achieved using endoscopic suturing.
ce-2026-130f3.jpg
Fig. 4.
Abscess drainage was performed with a transgastric lumen-apposing metal stent under endosonographic guidance.
ce-2026-130f4.jpg
  • 1. Shah R, Vedantam S, Bhalla S, et al. A comparison of technical and clinical success between lesser and greater curvature approaches in gastric peroral endoscopic myotomy: an updated systematic review and meta-analysis. Gastrointest Endosc 2025;102:789–796.ArticlePubMed
  • 2. Hustak R, Vackova Z, Krajciova J, et al. Endoscopic clips versus overstitch suturing system device for mucosotomy closure after peroral endoscopic pyloromyotomy (G-POEM): a prospective single-center study. Surg Endosc 2022;36:9254–9261.ArticlePubMedPDF
  • 3. Choi JH, Kozarek RA, Larsen MC, et al. Effectiveness and safety of lumen-apposing metal stents in endoscopic interventions for off-label indications. Dig Dis Sci 2022;67:2327–2336.ArticlePubMedPDF

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Endoscopic ultrasound-guided lumen-apposing metal stent placement for intra-abdominal abscess management following gastric peroral endoscopic myotomy
        Close
      • XML DownloadXML Download
      Figure
      • 0
      • 1
      • 2
      • 3
      Endoscopic ultrasound-guided lumen-apposing metal stent placement for intra-abdominal abscess management following gastric peroral endoscopic myotomy
      Image Image Image Image
      Fig. 1. Computed tomography demonstrated a 13×8 cm abscess along the greater curvature of the stomach.
      Fig. 2. Endoscopy revealed clip dehiscence at the mucosotomy site. Arrows demonstrate the area of clip dehiscence.
      Fig. 3. Clips were removed and secure closure was achieved using endoscopic suturing.
      Fig. 4. Abscess drainage was performed with a transgastric lumen-apposing metal stent under endosonographic guidance.
      Endoscopic ultrasound-guided lumen-apposing metal stent placement for intra-abdominal abscess management following gastric peroral endoscopic myotomy

      Clin Endosc : Clinical Endoscopy Twitter Facebook
      Close layer
      TOP