Skip Navigation
Skip to contents

Clin Endosc : Clinical Endoscopy

OPEN ACCESS

Articles

Page Path
HOME > Clin Endosc > Volume 59(4); 2026 > Article
Letter to the Editor Stereomicroscopic on-site evaluation in pancreatic endoscopic ultrasound-guided tissue acquisition: current evidence and future perspectives
Ho Seung Leeorcid, Jae Min Leeorcid
Clinical Endoscopy 2026;59(4):683-684.
DOI: https://doi.org/10.5946/ce.2026.183
Published online: July 29, 2026

Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University Anam Hospital, Seoul, Korea

Correspondence: Jae Min Lee Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University Anam Hospital, 73 Goryeodae-ro, Seongbuk-gu, Seoul 02841, Korea E-mail: jmlee1202@gmail.com
• Received: April 25, 2026   • Revised: June 28, 2026   • Accepted: June 29, 2026

© 2026 Korean Society of Gastrointestinal Endoscopy

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 754 Views
  • 18 Download
prev next
The pancreas is anatomically difficult to access and is closely surrounded by critical vascular and ductal structures. Therefore, tissue acquisition remains inherently challenging. With the advent of endoscopic ultrasound (EUS) and the introduction of EUS-guided tissue acquisition (EUS-TA), endoscopic sampling of pancreatic lesions has become feasible. However, important limitations persist. EUS-TA specimens are often scant and blood-contaminated, limiting histologic adequacy. More importantly, the presence of core tissue is a key determinant of diagnostic accuracy. Various efforts have been made to overcome these limitations, improve diagnostic yield, and reduce the need for repeat biopsies. Technical modifications, such as the fanning technique, have been introduced,1 and alternative approaches using specimen weight as a surrogate marker for tissue adequacy and histologic core acquisition have also been proposed.2 Despite these efforts, substantial improvements in diagnostic accuracy remain difficult to achieve.
To address this issue, on-site evaluations of specimen adequacy have been introduced, including rapid on-site evaluation (ROSE) and macroscopic on-site evaluation (MOSE). ROSE is the most established method and allows real-time cytopathological assessment and direct confirmation of diagnostic adequacy. However, its implementation requires the presence of a cytopathologist at the bedside, which limits its availability in many countries. Alternatively, MOSE can be performed without a cytopathologist. However, it is based on gross visual assessment and, therefore, depends heavily on operator experience and subjective judgment; consequently, its clinical utility remains controversial. In this context, stereomicroscopic on-site evaluation (SOSE) has emerged as a potential alternative that addresses some of the limitations of MOSE. Using a stereomicroscope, SOSE enables a more refined assessment of specimen characteristics. Its feasibility has been demonstrated not only in gastrointestinal subepithelial lesions3 but also more recently in resectable or borderline resectable pancreatic cancers.4
The potential of SOSE to improve specimen quality and diagnostic yield in settings where ROSE is not readily available is certainly of interest. Compared with conventional MOSE, SOSE enables stereomicroscopic visualization of white-core tissue, allowing a more objective assessment of specimen adequacy. Watanabe et al.5 demonstrated that SOSE provided ROSE, with a median assessment time of only 47 seconds, while achieving high histologic and overall diagnostic sensitivity. Similarly, Ishizaki et al.4 reported that approximately 73% of lesions met the stereomicroscopically visible white-core cutoff value after the first needle pass, allowing EUS-TA to be completed with a single puncture in most patients while maintaining high diagnostic accuracy. These findings suggest that the principal advantage of SOSE lies in facilitating white-core identification and optimizing the number of needle passes. However, whether SOSE can truly replace ROSE remains uncertain. While ROSE directly evaluates cytological features and determines diagnostic adequacy, MOSE and SOSE assess the presence of tissue components and, therefore, function as surrogate markers for adequacy. In other words, macroscopic adequacy does not necessarily translate into diagnostic adequacy.
In clinical practice, ROSE remains the most established approach for on-site evaluation, although it is not feasible in many institutions because it requires the presence of an on-site cytopathologist. Under such circumstances, MOSE may serve as the simplest alternative, and SOSE may represent a more refined extension of MOSE. However, it remains premature to conclude that SOSE can completely replace ROSE. Despite its potential advantages, several practical issues should be considered before the widespread adoption of SOSE. The availability of stereomicroscopes may be limited in many institutions, and additional equipment, operator training, and familiarity with stereomicroscopic interpretation are required. Furthermore, the impact of SOSE on overall procedure time, interobserver variability, cost-effectiveness, and reproducibility across different centers has not yet been sufficiently established. Further validation through large-scale, multicenter prospective studies is required. Meanwhile, the application of artificial intelligence (AI) to on-site evaluation has emerged as a promising direction in EUS-TA. Recent developments have focused on applying AI to digital cytology and real-time image interpretation, with the goal of assisting specimen adequacy assessment during EUS-TA. AI-assisted ROSE, in which slide interpretation is supported or replaced by AI, has the potential to reduce operator-dependent bias and improve efficiency.6 Nevertheless, this approach remains in the early stages of development and requires substantial data accumulation, rigorous model training, and thorough validation.
In conclusion, SOSE is a promising adjunct tool for on-site specimen evaluation during EUS-TA. However, further prospective multicenter studies are required to establish its clinical role and define its place alongside existing approaches.
  • 1. Lee JM, Lee HS, Hyun JJ, et al. Slow-pull using a fanning technique is more useful than the standard suction technique in EUS-guided fine needle aspiration in pancreatic masses. Gut Liver 2018;12:360–366.ArticlePubMedPMC
  • 2. Choi SJ, Lee JM, Lee KW, et al. Effect of histological examination on the diagnosis of pancreatic mass using endoscopic ultrasound fine-needle aspiration. Adv Clin Exp Med 2021;30:885–891.ArticlePubMed
  • 3. Nakatani S, Okuwaki K, Watanabe M, et al. Stereomicroscopic on-site evaluation in endoscopic ultrasound-guided tissue acquisition of upper gastrointestinal subepithelial lesions. Clin Endosc 2024;57:89–95.ArticlePubMedPMCPDF
  • 4. Ishizaki J, Okuwaki K, Watanabe M, et al. Effectiveness of endoscopic ultrasound-guided tissue acquisition with stereomicroscopic on-site evaluation for preoperative diagnosis of resectable or borderline resectable pancreatic cancer: a prospective study. Clin Endosc 2024;57:807–813.ArticlePubMedPMCPDF
  • 5. Watanabe M, Okuwaki K, Kida M, et al. Multicenter prospective study of the efficacy of stereomicroscopic on-site evaluation in endoscopic ultrasound-guided tissue acquisition in patients with pancreatic cancer. Pancreatology 2022;22:311–316.ArticlePubMed
  • 6. Ashida R, Kuwahara T, Koshikawa T, et al. AI-assisted real-time cytologic diagnosis during EUS-FNA of pancreatic masses (with video). Dig Endosc 2026;38:e70081.ArticlePubMedPMC

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Stereomicroscopic on-site evaluation in pancreatic endoscopic ultrasound-guided tissue acquisition: current evidence and future perspectives
        Clin Endosc. 2026;59(4):683-684.   Published online July 29, 2026
        Close
      • XML DownloadXML Download
      Related articles
      Stereomicroscopic on-site evaluation in pancreatic endoscopic ultrasound-guided tissue acquisition: current evidence and future perspectives
      Stereomicroscopic on-site evaluation in pancreatic endoscopic ultrasound-guided tissue acquisition: current evidence and future perspectives

      Clin Endosc : Clinical Endoscopy Twitter Facebook
      Close layer
      TOP