Skip Navigation
Skip to contents

Clin Endosc : Clinical Endoscopy

OPEN ACCESS

Articles

Page Path
HOME > Clin Endosc > Volume 59(5); 2026 > Article
Letter to the Editor Artificial intelligence in upper gastrointestinal endoscopy: what detection rates cannot tell us
Joon Sung Kimorcid
Clinical Endoscopy 2026;59(5):872-873.
DOI: https://doi.org/10.5946/ce.2026.328
Published online: September 14, 2026

Department of Internal Medicine, Incheon St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Incheon, Korea

Correspondence: Joon Sung Kim Department of Internal Medicine, Incheon St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, 56 Dongsu-ro, Bupyeong-gu, Incheon 21431, Korea E-mail: kijoons@hanmail.net
• Received: July 1, 2026   • Revised: July 21, 2026   • Accepted: July 22, 2026

© 2026 Korean Society of Gastrointestinal Endoscopy

This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 605 Views
  • 32 Download
prev
We read the article by Lee et al.1 with great interest. They found that real-time artificial intelligence (AI) improved lesion detection during upper gastrointestinal endoscopy, particularly for extremely small lesions (<0.5 cm). This is useful for obtaining real-world evidence from low-resource settings. We would like to raise a few points. First, two of the outcomes (benign and malignant detection rates) depend on the biopsy results and not on what the endoscopist sees. A large randomized trial showed that biopsy and pathology results can be affected by sampling error and by disagreement between pathologists.2 In addition, the number of cancers found was small (26 vs. 10), so the lack of a difference in malignant detection rate may simply reflect a small sample, not a true lack of effect. Second, fewer biopsies were performed after AI. This could mean better and more selective decisions; however, it could also mean that some lesions were skipped because they appeared harmless. Third, this was a single-center study conducted by one endoscopist who compared an earlier period with a later period. This type of design cannot fully separate the effects of AI from other changes over time, such as endoscopists gaining more experience. Fourth, background stomach conditions, such as atrophy and intestinal metaplasia, strongly affect gastric cancer risk.3 If these background conditions differed between the earlier and later patient groups, this alone could explain part of the change in detection rate. Reporting a background risk score, such as the Kyoto score, would help to clarify this. Fifth, in colonoscopy studies, most of the extra polyps found by AI are very small (<5 mm), and AI tends to be less helpful when the endoscopist is already highly skilled.4 The endoscopist in this study was very experienced, with more than 50,000 prior examinations. This may explain why the overall improvement was modest, and why the malignancy detection rate did not change. However, these points do not reduce the value of this study. We hope that future multicenter studies will address these issues using centralized pathology reviews, reporting background risks, and separating AI detection performance from biopsy outcomes.
  • 1. Lee H, Bang HC, Cho S, et al. Impact of real-time artificial intelligence integration on detection of gastric lesions: an exploratory single-center before-and-after study using low-definition routine endoscopy. Clin Endosc 2026;59:408–416.ArticlePubMedPMCPDF
  • 2. Dong Z, Wu L, Du H, et al. Effect of a computer-aided device for detecting gastric neoplasms: a multicenter, randomized controlled trial. Gastroenterology 2026;170:1518–1532.ArticlePubMed
  • 3. Hiramatsu T, Kakushima N, Kuribara H, et al. Recent advancement in endoscopic diagnosis for risk stratification of gastric cancer. Clin Endosc 2025;58:787–796.ArticlePubMedPMCPDF
  • 4. Chen ELY, Li JW. Computer-aided quality control in colonoscopy: clinical applications and limitations. Clin Endosc 2025 Dec 17 [Epub]. http://doi.org/10.5946/ce.2025.309Article

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        Artificial intelligence in upper gastrointestinal endoscopy: what detection rates cannot tell us
        Clin Endosc. 2026;59(5):872-873.   Published online September 14, 2026
        Close
      • XML DownloadXML Download
      Related articles
      Artificial intelligence in upper gastrointestinal endoscopy: what detection rates cannot tell us
      Artificial intelligence in upper gastrointestinal endoscopy: what detection rates cannot tell us

      Clin Endosc : Clinical Endoscopy Twitter Facebook
      Close layer
      TOP